Evaluation of new image processing conditions for digital mammograms from Fuji computed radiography.

نویسندگان

  • Hiroshi Kano
  • Tokiko Endo
  • Mitsuru Ikeda
  • Mikinao Oiwa
  • Takeo Ishigaki
چکیده

PURPOSE A new processing parameter (T-type parameter) setting for gray scale was developed to improve the image quality of digital mammograms. To clarify the usefulness of this parameter setting, we have evaluated the image quality of digital mammograms (hard copy images) processed with this parameter, and compared it with S/F mammography. MATERIAL AND METHODS Mammograms were made under the same radiographic conditions by the S/F and FCR systems (type 1, S/F; type 2 and 3, FCR with new T-type parameters; type 4 and 5, FCR with conventional parameters). A total of 49 images from 10 cases was selected for evaluation testing. Evaluation items were the contrast visibility of mammary glands and adipose tissues together with their granularity and sharpness. Eleven medical doctors participated in evaluating the images. RESULTS The FCR hard copy images processed with the T-type parameter settings were significantly preferred over the conventional S/F images for the contrast visibility of mammary glands and adipose tissue. As for the other items (except for granularity), the FCR hard copy images processed with the T-type parameter settings were subjectively evaluated as slightly better than or equal to the S/F images. In contrast, the conventional S/F images were significantly preferred over the FCR hard copy images processed with the conventional parameter settings. CONCLUSION The image quality of FCR hard copy images processed with the T-type parameter settings was preferred over that of conventional S/F images as evaluated by medical doctors who specialized in mammography interpretation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of Dose and Image Quality in Full-fiand Computed Radiography Systems for Common Digital Radiographic Examinations

IntroductionA fine balance of image quality and radiation dose can be achieved by optimization to minimize stochastic and deterministic effects. This study aimed in ensuring that images of acceptable quality for common radiographic examinations in digital imaging were produced without causing harmful effects. Materials and MethodsThe study was conducted in three phases. The pre-optimization inv...

متن کامل

Quality comparison of direct digital panoramic radiography and computed radiography panoramic

BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels). The first category is defined as computed radiography (CR) or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR). Both of these technologies have their o...

متن کامل

The Practice of Chest Radiography Using Different Digital Imaging Systems: Dose and Image Quality

Introduction: The study was undertaken to evaluate the practice of chest radiography using different digital imaging systems and its influence on dose and image quality.  Materials and Methods: The study was carried out in two hospitals from March 2016 to June 2016. Sixty ambulatory patients aged 21 to 60 years who were able to cooperate without difficulty and weighed between 60 to 80 kg were ...

متن کامل

Image Quality and Entrance Surface Dose Evaluation of Lateral Cervical Spine: A Study Using Grid and Non-Grid Techniques

Introduction: The purpose of this study is to investigate the effects of grid and non-grid techniques in the lateral cervical spine radiography on image quality and entrance surface dose (ESD). Although image quality and radiation doses have been studied by researchers, there is still a dearth of information on image quality and patient dose with different techniques. Material and Methods: The...

متن کامل

A Phantom Study for the Optimization of Image Quality and Radiation Dose for Common Radiographic Examinations in Digital Radiography

Introduction: Phantom studies facilitate the implementation of radiation dose surveillance as a function of radiographic technical parameters for minimizing patient radiation dose. The evidence of such investigations can then be used to evaluate technical parameters used in the radiographic procedures to reduce radiation dose without compromising the image quality. Material and Methods: This ex...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nagoya journal of medical science

دوره 68 3-4  شماره 

صفحات  -

تاریخ انتشار 2006