Strain gauge analysis of the effect of porcelain firing simulation on the prosthetic misfit of implant-supported frameworks.
نویسندگان
چکیده
OBJECTIVES This study investigated the effect of porcelain firing on the misfit of implant-supported frameworks and analyzed the influence of preheat treatment on the dimensional alterations. MATERIALS AND METHODS Four external-hex cylindrical implants were placed in polyurethane block. Ten frameworks of screw-retained implant-supported prostheses were cast in Pd-Ag using 2 procedures: (1) control group (CG, n = 5): cast in segments and laser welded; and test group (TG, n = 5): cast in segments, preheated, and laser welded. All samples were subjected to firing to simulate porcelain veneering firing. Strain gauges were bonded around the implants, and microstrain values (με = 10⁻⁶ε) were recorded after welding (M1), oxidation cycle (M2), and glaze firing (M3). Data were statistically analyzed (2-way analysis of variance, Bonferroni, α = 0.05). RESULTS The microstrain value in the CG at M3 (475.2 με) was significantly different from the values observed at M1 (355.6 με) and M2 (413.9 με). The values at M2 and M3 in the CG were not statistically different. Microstrain values recorded at different moments (M1: 361.6 με/M2: 335.3 με/M3: 307.2 με) did not show significant difference. CONCLUSIONS The framework misfit deteriorates during firing cycles of porcelain veneering. Metal distortion after porcelain veneering could be controlled by preheat treatment.
منابع مشابه
Evaluating the Frequency of Implant-Supported Fixed Prosthesis Complications in Yazd Dental School in 2020
Introduction: Evaluating the frequency of complications in implant supported prosthesis such as screw loosening and porcelain fracture is important for prevention and management of these problems. The purpose of this study was to evaluate the frequency of implant-supported fixed prosthesis complications in Yazd dental school in 2020. Methods: In this descriptive cross-sectional study, the pat...
متن کاملStress distribution in fixed-partial prosthesis and peri-implant bone tissue with different framework materials and vertical misfit levels: a three-dimensional finite element analysis.
The purpose of this study was to evaluate the influence of superstructure material and vertical misfits on the stresses created in an implant-supported partial prosthesis. A three-dimensional (3-D) finite element model was prepared based on common clinical data. The posterior part of a severely resorbed jaw with two osseointegrated implants at the second premolar and second molar regions was mo...
متن کاملStress distribution in fixed-partial prosthesis and peri-implant bone tissue with different framework materials and vertical misfit levels: a three-dimensional finite element
The purpose of this study was to evaluate the influence of superstructure material and vertical misfits on the stresses created in an implant-supported partial prosthesis. A three-dimensional (3-D) finite element model was prepared based on common clinical data. The posterior part of a severely resorbed jaw with two osseointegrated implants at the second premolar and second molar regions was mo...
متن کاملProsthetic misfit of implant-supported prosthesis obtained by an alternative section method
PURPOSE Adequate passive-fitting of one-piece cast 3-element implant-supported frameworks is hard to achieve. This short communication aims to present an alternative method for section of one-piece cast frameworks and for casting implant-supported frameworks. MATERIALS AND METHODS Three-unit implant-supported nickel-chromium (Ni-Cr) frameworks were tested for vertical misfit (n = 6). The fram...
متن کاملمقایسه اثر مواد مختلف سازنده ساختار فلزی روکش بر توزیع تنش پیرامون ایمپلنت با آنالیز اجزاء محدود سه بعدی
Objectives: Despite the high success rate, implant-supported prostheses fail in some cases. Control of the applied forces is an important factor determining the success or failure of implants. Complete understanding of the biomechanical principles in implant-supported prostheses is necessary for offering an appropriate custom-made treatment plan for each patient and reducing the risk of functio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Implant dentistry
دوره 21 3 شماره
صفحات -
تاریخ انتشار 2012