Charge Detection Mass Spectrometry for Single Ions with an Uncertainty in the Charge Measurement of 0.65 e.

نویسندگان

  • Elizabeth E Pierson
  • Nathan C Contino
  • David Z Keifer
  • Martin F Jarrold
چکیده

Charge detection mass spectrometry (CDMS) provides a direct measure of the mass of individual ions through nondestructive, simultaneous measurements of the mass to charge ratio and the charge. To improve the accuracy of the charge measurement, ions are trapped and recirculated through the charge detector. By substantially extending the trapping time, the uncertainty in the charge determination has been reduced by a factor of two, from 1.3 elementary charges (e) to 0.65 e. The limit of detection (the smallest charge that can be reliably measured) has been reduced by about the same proportion, from 13 to 7 e. The more precise charge measurements enable a substantial improvement in the mass resolution, which is critical for applications of CDMS to mixtures of high mass ions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Charge Detection Mass Spectrometry with Almost Perfect Charge Accuracy.

Charge detection mass spectrometry (CDMS) is a single-particle technique where the masses of individual ions are determined from simultaneous measurement of each ion's mass-to-charge ratio (m/z) and charge. CDMS has many desirable features: it has no upper mass limit, no mass discrimination, and it can analyze complex mixtures. However, the charge is measured directly, and the poor accuracy of ...

متن کامل

Charge detection mass spectrometry with resolved charge states.

Charge detection mass spectrometry (CDMS) measurements have been performed for cytochrome c and alcohol dehydrogenase (ADH) monomer using a modified cone trap incorporating a cryogenically cooled JFET. Cooling the JFET increases its transconductance and lowers thermal noise, improving the signal to noise (S/N) ratio. Single ions with as few as 9 elementary charges (e) have been detected. Accord...

متن کامل

A Review on Mass Spectrometry Detectors

Mass spectrometry is an analytical technique for "weighing" molecules. Obviously, this is not done with a conventional scale or balance. Instead, mass spectrometry is based upon the principle of the motion of a charged particle that is called an ion, in an electric or magnetic field. The mass to charge ratio (m/z) of the ion affects particles motion. Since the charge of an electron is known, th...

متن کامل

Charge detection mass spectrometry of bacteriophage P22 procapsid distributions above 20 MDa.

RATIONALE Charge state resolution is required to determine the masses of ions in electrospray mass spectrometry, a feat which becomes increasingly difficult as the mass increases. Charge detection mass spectrometry (CDMS) circumvents this limitation by simultaneously measuring the charge and the m/z of individual ions. In this work, we have used electrospray CDMS to determine the number of scaf...

متن کامل

Mass and Charge Measurements on Heavy Ions

The relationship between mass and charge has been a crucial topic in mass spectrometry (MS) because the mass itself is typically evaluated based on the m/z ratio. Despite the fact that this measurement is indirect, a precise mass can be obtained from the m/z value with a high m/z resolution up to 105 for samples in the low mass and low charge region under 10,000 Da and 20 e, respectively. Howev...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Society for Mass Spectrometry

دوره 26 7  شماره 

صفحات  -

تاریخ انتشار 2015