Standardization of cardiac troponin I assays: round Robin of ten candidate reference materials.
نویسندگان
چکیده
BACKGROUND Cardiac troponin I (cTnI) results vary 100-fold among assays. As a step toward standardization, we examined the performance of 10 candidate reference materials (cRMs) in dilution studies with 13 cTnI measurement systems. METHODS Solutions of 10 cTnI cRMs, each characterized by NIST, were shipped to the manufacturers of 13 cTnI measurement systems. Manufacturers used their respective diluents to prepare each cRM in cTnI concentrations of 1, 10, 25, and 50 microg/L. For the purpose of ranking the cRMs, the deviation of each cTnI measurement from the expected response was assessed after normalization with the 10 microg/L cTnI solution. Normalized deviations were examined in five formats. Parameters from linear regression analysis of the measured cTnI vs expected values were also used to rank performance of the cRMs. RESULTS The three cRMs demonstrating the best overall rankings were complexes of troponins C, I, and T. The matrices for these three cRMs values differed; one was reconstituted directly from the lyophilized form submitted by the supplier; one was submitted in liquid form, lyophilized at NIST, and subsequently reconstituted; and the third was evaluated in the liquid form received from the supplier. The cRM demonstrating the fourth best performance was a binary complex of troponins C and I supplied in lyophilized form and reconstituted before distribution. CONCLUSIONS The cRMs demonstrating the best performance characteristics in 13 cTnI analytical systems will be included in subsequent activities of the cTnI Standardization Committee of the AACC.
منابع مشابه
Toward standardization of cardiac troponin I measurements part II: assessing commutability of candidate reference materials and harmonization of cardiac troponin I assays.
BACKGROUND Cardiac tropoin I (cTnI) measurements show an approximately 20- to 40-fold difference between assays, and better standardization and harmonization are needed. Toward this goal, the AACC cTnI Standardization Committee collaborated with the National Institute of Standards and Technology (NIST) in an earlier study to select 2 candidate reference materials (cRMs). METHODS Two troponin ...
متن کاملStandardisation of cardiac troponin I measurement: past and present.
The laboratory measurement of cardiac troponin (cTn) concentration is a critical tool in the diagnosis of acute myocardial infarction (MI). Current cTnI assays produce different absolute troponin numbers and use different clinical cut-off values; hence cTnI values cannot be interchanged, with consequent confusion for clinicians. A recent Australian study compared patient results for seven cTnI ...
متن کاملCharacterization of a new certified reference material for human cardiac troponin I.
BACKGROUND To address the continuing need for the standardization of clinical human cardiac troponin I (cTnI) assays, NIST, with the assistance of the AACC/IFCC Cardiac Troponin I Standardization Committee, has developed a new certified reference material, Standard Reference Material (SRM) 2921: Human Cardiac Troponin Complex. METHODS The concentration of cTnI in SRM 2921 was determined throu...
متن کاملStandardization of cardiac troponin I measurements: the way forward?
The contribution of laboratory medicine to clinical cardiology has grown in importance over the years. Highly sensitive and specific biomarkers for the detection of myocardial damage, such as cardiac troponins, as well as assays for reliable markers of myocardial function, such as cardiac natriuretic peptides, are now available, assigning to the laboratory a pivotal role in the diagnosis and fo...
متن کاملDevelopment of a candidate secondary reference procedure (immunoassay based measurement procedure of higher metrological order) for cardiac troponin I: I. Antibody characterization and preliminary validation.
In this study, the first steps in the development of a secondary reference measurement procedure (RMP) 'higher metrological order measurement procedure' to support the cardiac troponin I (cTnI) standardization initiative is described. The RMP should be used to assign values to serum-based secondary reference materials (RMs) without analytical artifacts causing bias. A multiplexed bead-based ass...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 47 3 شماره
صفحات -
تاریخ انتشار 2001