Attenuation correction in confocal laser microscopes: a novel two-view approach.
نویسندگان
چکیده
Confocal microscopy is a three-dimensional (3D) imaging modality, but the specimen thickness that can be imaged is limited by depth-dependent signal attenuation. Both software and hardware methods have been used to correct the attenuation in reconstructed images, but previous methods do not increase the image signal-to-noise ratio (SNR) using conventional specimen preparation and imaging. We present a practical two-view method that increases the overall imaging depth, corrects signal attenuation and improves the SNR. This is achieved by a combination of slightly modified but conventional specimen preparation, image registration, montage synthesis and signal reconstruction methods. The specimen is mounted in a symmetrical manner between a pair of cover slips, rather than between a slide and a cover slip. It is imaged sequentially from both sides to generate two 3D image stacks from perspectives separated by approximately 180 degrees with respect to the optical axis. An automated image registration algorithm performs a precise 3D alignment, and a model-based minimum mean squared algorithm synthesizes a montage, combining the content of both the 3D views. Experiments with images of individual neurones contrasted with a space-filling fluorescent dye in thick brain tissue slices produced precise 3D montages that are corrected for depth-dependent signal attenuation. The SNR of the reconstructed image is maximized by the method, and it is significantly higher than in the single views after applying our attenuation model. We also compare our method with simpler two-view reconstruction methods and quantify the SNR improvement. The reconstructed images are a more faithful qualitative visualization of the specimen's structure and are quantitatively more accurate, providing a more rigorous basis for automated image analysis.
منابع مشابه
A novel dual energy CT-based attenuation correction method in PET/CT systems: A phantom study
In present PET/CT scanners, PET attenuation correction is performed by relying on the information given by CT scan. In the CT-based attenuation correction methods, dual-energy technique (DECT) is the most accurate approach, which has been limited due to the increasing patient dose. In this feasibility study, we have introduced a new method that can implement dual-en...
متن کاملNew approach for attenuation correction in SPECT images, using linear optimization
Background: Photon attenuation as an inevitable physical phenomenon influences on the diagnostic information of SPECT images and results to errors in accuracy of quantitative measurements. This can be corrected via different physical or mathematical approaches. As the correction equation in mathematical approaches is nonlinear, in this study a new method of linearization called ‘Piece ...
متن کاملComparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction
Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...
متن کاملDepth Intensity Correction of Biofilm Volume Data from Confocal Laser Scanning Microscopes
Fluorescent signal intensities from confocal laser scanning microscopes (CLSM) suffer from several distortions inherent to the method. Namely, these are the decay of intensities with increasing depth by finite transparency of the media used, the effects of extinction of the examined objects, the bleaching of the fluorochrome and stray light at surfaces within the volume under research. Under ce...
متن کاملEvaluation of attenuation correction process in cardiac SPECT images
Introduction: Attenuation correction is a useful process for improving myocardial perfusion SPECT and is dependent on activity and distribution of attenuation coefficients in the body (attenuation map). Attenuation artifacts are a common problem in myocardial perfusion SPECT. The aim of this study was to compare the effect of attenuation correction using different a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of microscopy
دوره 211 Pt 1 شماره
صفحات -
تاریخ انتشار 2003