Biophysical Characterization of Human Protamine-1 as a Responsive CEST MR Contrast Agent
نویسندگان
چکیده
The protamines are a low-molecular-weight, arginine-rich family of nuclear proteins that protect chromosomal DNA in germ cells by packing it densely using electrostatic interactions. Human protamine-1 (hPRM1) has been developed as a magnetic resonance imaging (MRI) chemical exchange saturation transfer (CEST) reporter gene, based on a sequence that is approximately 50% arginine, which has a side chain with rapidly exchanging protons. In this study, we have synthesized hPRM1 and determined how its CEST MRI contrast varies as a function of pH, phosphorylation state, and upon noncovalent interaction with nucleic acids and heparin (as antagonist). CEST contrast was found to be highly sensitive to phosphorylation on serine residues, intra- and intermolecular disulfide bridge formation, and the binding of negatively charged nucleotides and heparin. In addition, the nucleotide binding constants (Keq) for the protamines were determined through plotting the molar concentration of heparin versus CEST contrast and compared between hPRM1 and salmon protamine. Taken together, these findings are important for explaining the CEST contrast of existing arginine-rich probes as well as serving as a guideline for designing new genetic or synthetic probes.
منابع مشابه
A self-calibrating PARACEST MRI contrast agent that detects esterase enzyme activity.
The CEST effect of many PARACEST MRI contrast agents changes in response to a molecular biomarker. However, other molecular biomarkers or environmental factors can influence CEST, so that a change in CEST is not conclusive proof for detecting the biomarker. To overcome this problem, a second control CEST effect may be included in the same PARACEST agent, which is responsive to all factors that ...
متن کاملAnalytical determination of the chemical exchange saturation transfer (CEST) contrast in molecular magnetic resonance imaging
Magnetic resonance based on molecular imaging allows tracing contrast agents thereby facilitating early diagnosis of diseases in a non-invasive fashion that enhances the soft tissue with high spatial resolution. Recently, the exchange of protons between the contrast agent and water, known as the chemical exchange saturation transfer (CEST) effect, has been measured by applying a suitable pulse ...
متن کاملA General MRI-CEST Ratiometric Approach for pH Imaging: Demonstration of in Vivo pH Mapping with Iobitridol
Chemical exchange saturation transfer (CEST) is a novel contrast mechanism for magnetic resonance imaging (MRI). CEST MRI selectively saturates exchangeable protons that are transferred to MRI-detectable bulk water signal. MRI-CEST (pH)-responsive agents are probes able to map pH in the microenvironment in which they distribute. To minimize the confounding effects of contrast agent concentratio...
متن کاملRecent Advances in PET-MR Hybrid contrast agent
Introduction: All of the Imaging modalities have advantages and disadvantages alone. So if we want to have the best and perfect image, combining these modalities produces something we desired. PET-MR images consist of morphologic and metabolic data. MRI and PET provide high spatial and contrast resolution and high sensitivity and molecular information respectively. Hybrid PET-...
متن کاملA single diamagnetic catalyCEST MRI contrast agent that detects cathepsin B enzyme activity by using a ratio of two CEST signals.
CatalyCEST MRI can detect enzyme activity by monitoring the change in chemical exchange with water after a contrast agent is cleaved by an enzyme. Often these molecules use paramagnetic metals and are delivered with an additional non-responsive reference molecule. To improve this approach for molecular imaging, a single diamagnetic agent with enzyme-responsive and enzyme-unresponsive CEST signa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 4 شماره
صفحات -