Optical coherence tomography in the eyes of normal children.

نویسندگان

  • Mays A El-Dairi
  • Sanjay G Asrani
  • Laura B Enyedi
  • Sharon F Freedman
چکیده

OBJECTIVE To collect a normative database of macular thickness, retinal nerve fiber layer (RNFL) thicknesses, and optic nerve topography in the healthy eyes of children aged 3 to 17 years using optical coherence tomography (OCT) measurements. METHODS Scans were obtained for 286 healthy children (black, 114; white, 154; other, 18). Each child had a dilated eye examination, an axial length measurement using the IOL Master (Carl Zeiss Meditec, Dublin, California), and OCT measurements using the fast macular map, fast RNFL thickness, and fast optic disc protocols of the Stratus OCT (OCT-3; Carl Zeiss Meditec). RESULTS Black children had smaller macular volume and foveal thickness, larger RNFL thickness, and larger cup-disc area ratios compared with white children. Macular volume and average outer macular thickness correlated negatively with axial length in white children. Foveal thickness correlated positively with age in black children only. Average RNFL correlated negatively with axial length in white children only (P < .05 for all). Normative data for all variables were recorded and compared with reported adult values. CONCLUSIONS Stratus OCT-3 measurements of macular and RNFL thickness and optic nerve topography vary with race, axial length, and age in healthy children. Normative pediatric OCT data should facilitate the use of OCT in assessing childhood glaucoma and other diseases.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی پایایی و تکرار پذیری دستگاه Spectral domain optical coherence tomography در اندازه گیری ضخامت ماکولا در چشمهای طبیعی قبل و بعد از گشاد کردن مردمک

Background: optical coherence tomography is one of the most valuable imaging techniques in the evaluation of macula. Objective: to investigate the repeatability and reproducibility of OCT  in measuring the macular thickness in normal eyes before and after pupil dilation. Methods: A total of 44 eyes were enrolled. All subjects underwent macular thickness measurement using the Cirrus SD-OCT ma...

متن کامل

Evaluation of Optical Coherence Tomography Angiography Findings in Patients with Branch Retinal Vein Occlusion

Purpose: To analyze the correlation of optical coherence tomography angiography (OCTA) findings with visual acuity (VA) in patients with branch retinal vein occlusion (BRVO). Methods: This cross-sectional study was performed on 20 eyes of 20 patients with unilateral BRVO involving the macula referred to the ophthalmology clinic of Rassoul Akram Hospital. OCTA imaging was conducted for all patie...

متن کامل

Correlation between Visual Acuity and Optical Coherence Tomography-Measured Retinal Thickness in Diabetic Macular Edema

Background and Objective: Diabetic macular edema (DME) is one of the common complications of diabetes which significantly accounts for preventable visual impairment and blindness. Central macular thickness (CMT) is a feature found in DME patients. This study aims to determine the relationship between optical coherence tomography (OCT)-measured CMT and visual acuity (VA) in patients with DME bef...

متن کامل

Retinal Ganglion Cell Complex in Alzheimer Disease: Comparing Ganglion Cell Complex and Central Macular Thickness in Alzheimer Disease and Healthy Subjects Using Spectral Domain-Optical Coherence Tomography

Introduction: Alzheimer disease (AD) is the most common form of dementia worldwide. The modalities to diagnose AD are generally expensive and limited. Both the central nervous system (CNS) and the retina are derived from the cranial neural crest; therefore, changes in retinal layers may reflect changes in the CNS tissue. Optical coherence tomography (OCT) machine can show delicate retinal layer...

متن کامل

Clinical Applications of Optical Coherence Tomography in Ophthalmology

Assessment of the peripapillary nerve fiber layer and macular thickness can be determined in ophthalmology using optical coherence tomography (OCT). Decreased nerve fiber layer thickness and macular ganglion cell thickness in optic nerve ischemia have been correlated with visual field loss. OCT allows deep optic nerve head evaluation which helps understand pathophysiology of diseases.  Furtherm...

متن کامل

Development of an Advanced Optical Coherence Tomography System for Radiation Dosimetry

Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Archives of ophthalmology

دوره 127 1  شماره 

صفحات  -

تاریخ انتشار 2009