Model-based nonlinear inverse reconstruction for T2 mapping using highly undersampled spin-echo MRI.
نویسندگان
چکیده
PURPOSE To develop a model-based reconstruction technique for T2 mapping based on multi-echo spin-echo MRI sequences with highly undersampled Cartesian data encoding. MATERIALS AND METHODS The proposed technique relies on a nonlinear inverse reconstruction algorithm which directly estimates a T2 and spin-density map from a train of undersampled spin echoes. The method is applicable to acquisitions with single receiver coils but benefits from multi-element coil arrays. The algorithm is validated for trains of 16 spin echoes with a spacing of 10 to 12 ms using numerical simulations as well as human brain MRI at 3 Tesla (T). RESULTS When compared with a standard T2 fitting procedure using fully sampled T2-weighted images, and depending on the available signal-to-noise ratio and number of coil elements, model-based nonlinear inverse reconstructions for both simulated and in vivo MRI data yield accurate T2 estimates for undersampling factors of 5 to 10. CONCLUSION This work describes a promising strategy for T2-weighted MRI that simultaneously offers accurate T2 relaxation times and properly T2-weighted images at arbitrary echo times. For a standard spin-echo MRI sequence with Cartesian encoding, the method allows for a much higher degree of undersampling than obtainable by conventional parallel imaging.
منابع مشابه
Nonlinear Inverse Reconstruction for T2 Mapping from Highly Undersampled Cartesian Spin-Echo MRI
Introduction: Quantitative evaluations of the T2 relaxation time are of high importance for diagnostic MRI. Standard T2 mapping procedures rely on the time-demanding acquisition of several fully-sampled k-space datasets at multiple echo times. Recently, a new method has been proposed which employs a nonlinear inversion of the underlying signal equation to allow for reconstructions of spin-densi...
متن کاملFast MR parameter mapping from highly undersampled data by Direct Reconstruction of Principal Component Coefficient Maps using Compressed Sensing
Introduction: There has been an increased interest in quantitative MR parameter mapping techniques which enable direct comparison of tissuerelated values between different subjects and scans. However the lengthy acquisition times needed by conventional parameter mapping methods limit their use in the clinic. For estimating T2 values from highly undersampled radial Fast Spin Echo (FSE) datasets,...
متن کاملT2 estimation for small lesions using a Model-Based reconstruction with sparsifying penalty functions and highly under- sampled radial FSE data
Introduction: T2 weighted MRI is used clinically for characterization of various pathologies. Currently, radiologists use visual methods to evaluate the T2 characteristics of a lesion based on signal intensity changes. It has been demonstrated that quantitative methods for measuring T2 values are superior to visual evaluation [1, 2]. For body imaging, however, many of the proposed methods to me...
متن کاملAccelerated and motion-robust in vivo T2 mapping from radially undersampled data using bloch-simulation-based iterative reconstruction.
PURPOSE Development of a quantitative transverse relaxation time (T2)-mapping platform that operates at clinically feasible timescales by employing advanced image reconstruction of radially undersampled multi spin-echo (MSE) datasets. METHODS Data was acquired on phantom and in vivo at 3 Tesla using MSE protocols employing radial k-space sampling trajectories. In order to overcome the nontriv...
متن کاملAccelerated Breath-Hold Multi-Echo FSE Pulse Sequence Using Compressed Sensing and Parallel Imaging for T2 Measurement in the Heart
Introduction: Measurement of proton transverse relaxation time (T2) can be used to detect pathological changes in tissue for a variety of clinical applications, including identification of edema and iron overload. The most widely used T2 mapping pulse sequence is the Carr-Purcell-Meiboom-Gill (CPMG) sequence [1,2]. For body MRI, however, a CPMG pulse sequence is typically performed with navigat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of magnetic resonance imaging : JMRI
دوره 34 2 شماره
صفحات -
تاریخ انتشار 2011