Relevancy of corneal biomechanical in glaucoma

نویسندگان

  • Jorge Augusto Siqueira da Silva
  • Renata Siqueira da Silva
  • Renato Ambrósio
چکیده

Case report of a patient, with a thick cornea, for Fuchs dystrophy in its early stages, yet with preserved corneal transparency (subclinical corneal edema), associated with normal intraocular pressure (IOP) by Goldman applanation tonometry (GAT), which was however, the diagnosis of primary open-angle glaucoma on the basis of structural changes of the optic nerve. The tomographic study showed a pattern of spatial pachymetry compatible with subclinical edema. The corneal biomechanical study with ORA (Ocular Response Analyzer, Reichert ®) associated with corrected IOP measurement, allowed the understanding of the corneal influence, which, although thicker, leading to a falsely low TAG (underestimated). The IOP study with tonography system digital (PASCAL) corroborated with the findings of ORA. This example highlights the importance of new technologies in patients’ evaluation with suspected glaucoma, and highlights that the correction of TAG, based on linear algorithms related to central corneal thickness alone, can determine serious errors in clinical interpretation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea

Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...

متن کامل

Ocular Response Analyzer

Until recently, corneal biomechanical properties could not be measured in vivo. The ocular response analyzer is a new, noninvasive device that analyses corneal biomechanical properties simply and rapidly. The ORA allows cornea compensated IOP measurements and can estimate corneal hysteresis (CH) and corneal resistance factor (CRF). It is designed to improve the accuracy of IOP measurement by us...

متن کامل

Corneal Biomechanical Changes Following Trabeculectomy, Phaco-trabeculectomy, Ahmed Glaucoma Valve Implantation and Phacoemulsification

PURPOSE To determine corneal biomechanical changes following major glaucoma procedures. METHODS In a prospective comparative case series, corneal biomechanical properties were assessed using the Ocular Response Analyzer (ORA, Reichert Inc., Depew, New York, USA) before and 3 months after surgery in 89 eyes of 89 patients undergoing trabeculectomy + mitomycin C (MMC) (23 eyes, group 1), phacot...

متن کامل

Impact of Myopia on Corneal Biomechanics in Glaucoma and Nonglaucoma Patients

Purpose We evaluated the impact of myopia on corneal biomechanical properties in primary open-angle glaucoma (POAG) and nonglaucoma patients, and the effect of modification of glaucoma on myopic eyes. Methods This cross-sectional study included 66 POAG eyes (33 myopia, 33 nonmyopia) and 66 normal eyes (33 myopia, 33 nonmyopia). Seven corneal biomechanical parameters were measured by ultra-hig...

متن کامل

Corneal properties and glaucoma: a review of the literature and meta-analysis.

PURPOSE Studies have suggested that corneal biomechanical properties influence intraocular pressure (IOP) measurements, namely central corneal thickness (CCT) and corneal hysteresis (CH). The present study aimed to investigate the associations of CH and CCT with glaucoma development. METHODS We performed a review of the literature and meta-analysis of observational studies (2006-2016) that in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014