European real world trans-catheter aortic valve implantation: systematic review and meta-analysis of European national registries
نویسندگان
چکیده
OBJECTIVE Transcatheter aortic valve implantation (TAVI) has been adopted rapidly in Europe. TAVI national registries can augment understanding of technologies and represent real-world experience, providing further clinical insights. We undertook a meta-analysis of published European national TAVI registries to assess current results following TAVI in Europe. METHODS Electronic databases were searched. The review focused on the comparison of the following TAVI strategies: transfemoral (TF) and transapical (TA) SAPIEN and CoreValve implantation. Individual event rates for outcomes of interest were pooled using a mixed effect model. RESULTS Seven European national TAVI registries (UK, Swiss, Belgium, Italy, Spain, France, Germany) were identified, including a total of 9786 patients who received TF-SAPIEN (n = 2885), TA-SAPIEN (n = 2252) and CoreValve (n = 4649) implantation. Pooled incidence of 30-day mortality was 0.08% [95% Confidence Interval (CI): 0.05-0.11], 0.12% [95% CI: 0.07-0.19] and 0.06% [95% CI: 0.03-0.11] for TF-SAPIEN, TA-SAPIEN and CoreValve respectively (test for subgroup difference P = 0.18); there was high heterogeneity across European countries. Pooled incidence of stroke was comparable among the TAVI strategies (test for subgroup difference P = 0.79); the incidence of post-procedural moderate paravalvular leak ≥ 2 (P = 0.9) was similar across groups. CoreValve implantation was associated with an increased risk of pacemaker implantation (0.22 [95% CI: 0.19-0.26]; test for subgroup difference P < 0.0001). The lowest 30-day mortality was associated with TAVI performed in Spain (b coefficient -4.3; P = 0.03), in Italy (b coefficient -2.1; P < 0.0001), in UK (b coefficient -1.95; P = 0.01) and in France (b coefficient -2.8; P = 0.03). The German registry has the highest mortality for every TAVI strategy amongst all other European registries and especially for the TA-SAPIEN group. CONCLUSIONS Transarterial TAVI approaches were associated with a low early mortality regardless of the type of device used. There was marked heterogeneity among European countries for early mortality.
منابع مشابه
Trans-catheter Bioprosthetic Heart Valve Implantation in Iran (Tehran Heart Centre Experience)
Introduction: With the development of interventional cardiology in the world, in addition to coronary and aortic diseases, the treatment of heart valve diseases through catheters has recently begun. The treatment of aortic stenosis (which was only possible with open surgery and valve replacement) was first performed in the world in 2002 by Alain Cribier in France with catheter insertion of the ...
متن کاملFirst successful trans-catheter aortic valve implantation through ascending aorta using Edwards SAPIEN THV system.
Trans-catheter aortic valve implantation is rapidly becoming an established modality of treatment for patients with critical aortic stenosis who are high risk for conventional aortic valve replacement. This approach also has its limitations; however, with growing experience and improvements in the delivery system, it may be possible to overcome these limitations. We describe a case where conven...
متن کاملSevere intraprosthetic regurgitation by immobile leaflet after trans-catheter aortic valve implantation.
Aortic regurgitation mainly in the form of paravalvular leaks is a frequent complication of trans-catheter aortic valve implantation (TAVI). We describe a case of an 86-year-old woman with severe aortic stenosis, who underwent trans-apical TAVI with a 23-mm Edwards-SAPIEN valve. Immediately post-implantation, severe intravalvular leak was observed on trans-esophageal echocardiogram (TEE) due to...
متن کاملTrans-catheter aortic-valve implantation by the subclavian approach complicated with vessel dissection and transient left-arm paralysis.
We report a case of an 84-year-old female with symptomatic severe aortic stenosis, who was treated with trans-catheter aortic-valve implantation (TAVI), through the left subclavian artery. A CoreValve bioprosthesis was successfully implanted, but the procedure was complicated by a focal left subclavian dissection and transient left-arm paralysis, which was successfully managed.
متن کاملFirst-in-man implantation of a trans-catheter aortic valve in a mitral annuloplasty ring: novel treatment modality for failed mitral valve repair.
The trans-catheter valve-in-valve concept has become a feasible therapeutic option for patients with failing degenerated bioprosthesis, who are deemed inoperable. However, little is known about the feasibility of this technique in failed valve annuloplasty. We report the first-in-man implantation of a trans-catheter aortic valve within a mitral annuloplasty ring. Through a trans-apical trans-ca...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 11 شماره
صفحات -
تاریخ انتشار 2016