Intracavity CO laser photoacoustic trace gas detection: cyclic CH(4), H(2)O and CO(2) emission by cockroaches and scarab beetles.

نویسندگان

  • F G Bijnen
  • F J Harren
  • J H Hackstein
  • J Reuss
چکیده

A liquid-nitrogen-cooled CO laser and an intracavity resonant photoacoustic cell are employed to monitor trace gases. The setup was designed to monitor trace gas emissions of biological samples on line. The arrangement offers the possibility to measure gases at the 10(9) by volume (ppbv) level (e.g., CH(4), H(2) O) and to detect rapid changes in trace gas emission. A detection limit of 1 ppbv for CH(4) in N(2) equivalent to a minimal detectable absorption of 3 × 10(-9) cm(-1) can be achieved. Because of the kinetic cooling effect we lowered the detection limit for CH(4) in air is decreased to 10 ppbv. We used the instrument in a first application to measure the CH(4) and H(2) O emission of individual cockroaches and scarab beetles. These emissions could be correlated with CO(2) emissions that were recorded simultaneously with an infrared gas analyzer. Characteristic breathing patterns of the insects could be observed; unexpectedly methane was also found to be released.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensitive Intracavity Photoacoustic Measurements with a C02 Waveguide Laser

A photoacoustic intracavity configuration is presented; a resonant photoacoustic cell excited in its First longitudinal mode is placed inside the cavity of a C 0 2 waveguide laser. Due to the high laser power and the sharp intracavity focus, saturation effects occur in the excitation and relaxation process of absorbing C 2H 4 molecules. A more optimal configuration is applied to measure the C2H...

متن کامل

Quantum Cascade Laser-Based Photoacoustic Sensor for Trace Detection of Formaldehyde Gas

We report on the development of a photoacoustic sensor for the detection of formaldehyde (CH(2)O) using a thermoelectrically cooled distributed-feedback quantum cascade laser operating in pulsed mode at 5.6 μm. A resonant photoacoustic cell, equipped with four electret microphones, is excited in its first longitudinal mode at 1,380 Hz. The absorption line at 1,778.9 cm(-1) is selected for CH(2)...

متن کامل

Carbon dioxide and ammonia detection using 2 μ m diode laser based quartz - enhanced photoacoustic spectroscopy

Quartz-enhanced photoacoustic spectroscopy was employed for trace gas concentration measurements of CO 2 and NH 3 using a continuous wave thermoelectrically cooled, distributed feedback diode laser operating at 2 µm. A normalized noise equivalent absorptionvspace1pt coefficient, NNEA(1σ) = 1.4 × 10 −8 cm −1 W/ √ Hz was obtained for CO 2 using the R18 line of the 2ν 1 + ν 3 band at 4991.26 cm −1...

متن کامل

Field detection of CO and CH4 by NIR 2f modulation laser spectroscopy

  A novel compact fiber-coupled NIR system based on a DFB diode laser source is employed as a portable and sensitive gas sensor for trace detection of combustion pollutant molecules. We demonstrate the performance of such an NIR gas sensor by tracing the absorption lines of CO and CH4 using 2f-WMS technique at moderate temperature of T ~ 600°C in the recuperator channel of an industrial furnace...

متن کامل

Room-temperature mid-infrared laser sensor for trace gas detection.

Design and operation of a compact, portable, room-temperature mid-infrared gas sensor is reported. The sensor is based on continuous-wave difference-frequency generation (DFG) in bulk periodically poled lithium niobate at 4.6 mum, pumped by a solitary GaAlAs diode laser at 865 nm and a diode-pumped monolithic ring Nd:YAG laser at 1064.5 nm. The instrument was used for detection of CO in air at ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Applied optics

دوره 35 27  شماره 

صفحات  -

تاریخ انتشار 1996