ESI/ion trap/ion mobility/time-of-flight mass spectrometry for rapid and sensitive analysis of biomolecular mixtures.
نویسندگان
چکیده
An ion trap/ion mobility/time-of-flight mass spectrometry technique is shown to be a rapid and sensitive means of analyzing peptide/protein mixtures. In this approach, an ion trap is used to accumulate ions that have been electrosprayed from a mixture into concentrated packets. The ion packets are injected into a drift tube where components of the mixture are separated based on differences in mobility through a buffer gas. Ions that exit the drift tube are dispersed in a time-of-flight mass spectrometer for mass-to-charge (m/z) determination. The gas-phase separation strategy reduces congestion in the mass spectrum, and experimental mobilities complement m/z measurements in assigning peaks. Examples of the application of the approach to identification of peptides (from tryptic digests) and to separation of charge-state distributions from electrospray of a mixture containing ubiquitin and myoglobin are presented. Most peptides that are observed from tryptic digests of proteins such as cytochrome c and myoglobin can be identified from data that are acquired in under 1 min; studies of mixtures with known compositions indicate that detection limits are approximately 0.5-3 pmol for individual components. Factors that may influence the distributions that are observed, such as storage time in the trap, injection voltages used for the mobility experiment, and variations in ion cross section with charge state, are discussed.
منابع مشابه
A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کاملA Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کاملQuantification of Melittin in Iranian Honey Bee (Apis mellifera meda) Venom by Liquid Chromatography-electrospray Ionization-ion Trap Tandem Mass Spectrometry (LC-ESI-IT-MS/MS)
The current research aimed to quantify melittin (MEL) in Iranian honey bee (Apis mellifera meda) venom. To this end, a liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (LC-ESI-IT-MS/MS) approach was employed. Melittin is the main toxic peptide of honey bee venom with various biological and pharmacological activities. It was extracted with...
متن کاملThe Use of On-line Capillary Electrophoresis/Electrospray Ionization with Detection via an Ion Trap Storage/Reflection Time-of-flight Mass Spectrometer for Rapid Mutation-site Analysis of Hemoglobin Variants
Capillary electrophoresis/electrospray ionization using an ion trap storage/reflectron time-of-flight mass spectrometer detector (CE/ESI-IT/reTOF) is used to provide a rapid and sensitive method for analyzing structural variants in the hemoglobin (Hb) â-chain. The Hb αand â-chains are separated and the â-chain is digested by trypsin. The digest is analyzed by CE/ESI-IT/reTOF where a comparison ...
متن کاملIon trap/ion mobility/quadrupole/time-of-flight mass spectrometry for peptide mixture analysis.
An ion trap/ion mobility/quadrupole/time-of-flight mass spectrometer has been developed for the analysis of peptide mixtures. In this approach, a mixture of peptides is electrosprayed into the gas phase. The mixture of ions that is created is accumulated in an ion trap and periodically injected into a drift tube where ions separate according to differences in gas-phase ion mobilities. Upon exit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 71 2 شماره
صفحات -
تاریخ انتشار 1999