Tandem Study with Thermoluminescent Materials in Standard Diagnostic Beams

نویسندگان

  • Ana F. Maia
  • Linda V.E. Caldas
چکیده

Tandem systems formed with different thermoluminescent dosemeters were evaluated in standard diagnostic radiation beams. The utilized materials are commercially available, and the aim of this study was to carry out a performance comparison. The results show that the energy dependence of the materials, except TLD-100, were very high. Therefore, there are several possibilities of pair combinations forming a tandem system, but all of them using TLD-100 with a high energy dependent TL material. For all pair combinations evaluated in this study, the differences in the measurement ratios of subsequent energy values were always higher than 14%. The main differences among these tandem systems were in the dose sensitivity. The more advantageous TLD pair, among all evaluated, was TLD-100 and TLD-200, but several other combinations were also very efficient.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of the thyroid secondary cancer risk on the patient of standard breast external beam radiotherapy

Introduction: The purpose of this study was to estimate the secondary cancer risk of thyroid for standard radiotherapy methods which are commonly used for breast cancer patients. Materials and Methods: Sixty-four breast cancer patients (their age range was around 50 years old) who referred to Seyed- Al- Shohada hospital (Isfahan, Iran) were included in this ...

متن کامل

Diagnostic Reference Level Arising from Dental Panoramic Radiography

Introduction The present work describes a study in which, based on patient dose measurements, thermoluminescent dosimeters were used to obtain the diagnostic reference level arising from panoramic radiography. Materials and Methods Ten panoramic units and a sample of 15 patients per X-ray unit were studied. Two thermoluminescent dosimeter chips were placed on the skin surface of selected organs...

متن کامل

Dosimetric study of thermoluminescent detectors in clinical photon beams using liquid water and PMMA phantoms.

The purpose of this study was the dosimetric evaluation of thermoluminescent detectors of calcium sulphate doped with dysprosium (CaSO4:Dy) produced by IPEN compared to the TL response of lithium fluoride doped with magnesium and titanium (LiF:Mg,Ti) dosimeters and microdosimeters produced by Harshaw Chemical Company to clinical photon beams dosimetry (6 and 15 MV) using liquid water and PMMA p...

متن کامل

TLD as a tool for remote verification of output for radiotherapy beams : 25 years of experience

The University of Texas M.D. Anderson Cancer Center (UTMDACC) has extensive experience with thermoluminescent dosimetry (TLD) as a quality assurance tool for output and energy monitoring of radiation therapy beams. Over the past 25 years the TLD results of the monitored institutions, commissioning data for TLD readers, the characterization data of lithium fluoride TLD-100 powder and the records...

متن کامل

Stability Study of Ionization Chambers in Standard Mammography Radiation Beams

The ionization chambers are widely utilized in diagnostic radiology quality control and dosimetry. They are simple to use, and can be found commercially in various types depending on their applications. They are the recommended devices for the determination of the beam qualities in mammographic range. To assure the reliability of the measurements, the stability of the response of the ionization...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007