Using a wrist-worn device based on peripheral arterial tonometry to diagnose obstructive sleep apnea: in-laboratory and ambulatory validation.

نویسندگان

  • Stephen D Pittman
  • Najib T Ayas
  • Mary M MacDonald
  • Atul Malhotra
  • Robert B Fogel
  • David P White
چکیده

STUDY OBJECTIVES To assess the accuracy of a wrist-worn device (Watch_PAT 100) to diagnose obstructive sleep apnea in the home. DESIGN Participants completed 2 overnight diagnostic studies with the test device: 1 night in the laboratory with concurrent polysomnography and 1 night in the home with only the Watch_PAT. The order of the laboratory and home study nights was random. The frequency of respiratory events on the PSG was quantified using indexes based on 2 definitions of hypopnea: the respiratory disturbance index (RDI) using American Academy of Sleep Medicine Task Force criteria for clinical research, also referred to as the Chicago criteria (RDI.C), and the Medicare guidelines (RDI.M). The Watch_PAT RDI (PAT RDI) and oxygen desaturation index (PAT ODI) were then evaluated against the polysomnography RDI.C and RDI.M, respectively, for both Watch_PAT diagnostic nights, yielding IN-LAB and HOME-LAB comparisons. SETTING Sleep laboratory affiliated with a tertiary-care academic medical center. PATIENTS 30 patients referred with suspected OSA. INTERVENTIONS N/A. MEASUREMENTS AND RESULTS The polysomnography and PAT measures were compared using the mean [2 SD] of the differences and the intra-class correlation coefficient (ICC). The receiver-operator characteristic curve was used to assess optimum sensitivity and specificity and calculate likelihood ratios. For the IN-LAB comparison, there was high concordance between RDI.C and PAT RDI (ICC = 0.88, mean difference 2.5 [18.9] events per hour); RDI.M and PAT ODI (ICC = 0.95, mean difference 1.4 [12.9] events per hour; and sleep time (ICC = 0.70, mean difference 7.0 [93.1] minutes) between the test device and PSG. For the HOME-LAB comparison, there was good concordance between RDI.C and PAT RDI (ICC = 0.72, mean difference 1.4 [30.1] events per hour) and RDI.M and PAT ODI (ICC = 0.80, mean difference 1.6 [26.4] events per hour) for the test device and PSG. Home studies were performed with no technical failures. CONCLUSIONS In a population of patients suspected of having obstructive sleep apnea, the Watch_PAT can quantify an ODI that compares very well with Medicare criteria for defining respiratory events and an RDI that compares favorably with Chicago criteria for defining respiratory events. The device can be used with a low failure rate for single use in the lab and home for self-administered testing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of a wrist-worn device in the detection of obstructive sleep apnea.

OBJECTIVE To assess the accuracy of a wrist-worn device (Watch_PAT100) to diagnose obstructive sleep apnea (OSA). METHODS Thirty adult subjects with and without suspected OSA simultaneously had a standard in-laboratory polysomnogram (PSG) and wore the Watch_PAT100 during a full-night recording. PSG sleep and respiratory events were scored according to standard criteria. Watch_PAT data were an...

متن کامل

Validation a portable monitoring device for sleep apnea diagnosis in a population based cohort using synchronized home polysomnography.

SUBJECT OBJECTIVE To assess the accuracy of a portable monitoring device based on peripheral arterial tonometry to diagnose obstructive sleep apnea (OSA). To propose a new standard for limited-channel device validation using synchronized polysomnography (PSG) home recordings and a population-based cohort. DESIGN Single-night, unattended PSG and Watch_PAT 100 (WP_100). SETTING Home environme...

متن کامل

Accuracy of peripheral arterial tonometry in the diagnosis of obstructive sleep apnea.

INTRODUCTION The use of handheld devices that assess peripheral arterial tonometry has emerged as an auxiliary method for assessment and diagnosis of obstructive sleep apnea syndrome. OBJECTIVE To evaluate the accuracy of peripheral arterial tonometry in the diagnosis of obstructive sleep apnea. METHODS Contemporary cohort cross-sectional study. Thirty patients with suspected obstructive sl...

متن کامل

Detecting REM sleep from the finger: an automatic REM sleep algorithm based on peripheral arterial tone (PAT) and actigraphy.

Scoring of REM sleep based on polysomnographic recordings is a laborious and time-consuming process. The growing number of ambulatory devices designed for cost-effective home-based diagnostic sleep recordings necessitates the development of a reliable automatic REM sleep detection algorithm that is not based on the traditional electroencephalographic, electrooccolographic and electromyographic ...

متن کامل

Effects of Biofeedback Therapy on Cardiovascular and Respiratory Indices in NREM Sleep Parasomnias with Obstructive Sleep Apnea: A Case study

Introduction: Non-REM parasomnias are a relatively common condition in the general human population. Current treatment plans are usually based on small case series and reports. Considering the effects of sleep disorders on different aspects of human life and the failure of pharmacological treatments in this field, the present study was designed to investigate a case of this sleep disorders with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Sleep

دوره 27 5  شماره 

صفحات  -

تاریخ انتشار 2004