Magnetic Levitation and Noncoalescence of Liquid Helium.

نویسندگان

  • Weilert
  • Whitaker
  • Maris
  • Seidel
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tuned Parameters of PID for Optimization of Losses in Magnetic Levitation System

In this paper a new method is proposed for determining PID controller parameters in order to decrease losses in levitation system of magnetic trains. It is assumed that this system is a hybrid system and it consists of electric and permanent magnet. For optimization of losses initially AC losses of magnetic levitation system are calculated. Linear model of levitation system as well as modeling ...

متن کامل

Temperature Dependence of Magnetic Flux Drag Torque for a Single Grain YBa2Cu3O7 Superconductor

A modified close cycle helium gas cryogenic system was used to measure the flux drag torque acting on a free spinning disk magnet by a single grain YBCO superconductor. It was found that at low spinning speed ( less than 8 Hz ) and constant levitation height, the flux drag torque decreased with temperature which behavior is roughly similar to the temperature dependence of the reciprocal of crit...

متن کامل

Diamagnetic levitation enhances growth of liquid bacterial cultures by increasing oxygen availability.

Diamagnetic levitation is a technique that uses a strong, spatially varying magnetic field to reproduce aspects of weightlessness, on the Earth. We used a superconducting magnet to levitate growing bacterial cultures for up to 18 h, to determine the effect of diamagnetic levitation on all phases of the bacterial growth cycle. We find that diamagnetic levitation increases the rate of population ...

متن کامل

Accurate characteristics of Helium in nano-channels

This article describes an accurate subPico flowmeter bifurcatedin to liquid and gas flowrates less than 1mol/s for both MEMS/NEMS and cryogenic technology applications. The MEMS/NEMS are described as either two Gauges (instrument), or quartz fluctuating forks, even if the liquid or gas flows through an element, as well as cryogenic technology consisting of arrays of e...

متن کامل

Accurate characteristics of Helium in nano-channels

This article describes an accurate subPico flowmeter bifurcatedin to liquid and gas flowrates less than 1mol/s for both MEMS/NEMS and cryogenic technology applications. The MEMS/NEMS are described as either two Gauges (instrument), or quartz fluctuating forks, even if the liquid or gas flows through an element, as well as cryogenic technology consisting of arrays of e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physical review letters

دوره 77 23  شماره 

صفحات  -

تاریخ انتشار 1996