Magnetic Levitation and Noncoalescence of Liquid Helium.
نویسندگان
چکیده
منابع مشابه
Tuned Parameters of PID for Optimization of Losses in Magnetic Levitation System
In this paper a new method is proposed for determining PID controller parameters in order to decrease losses in levitation system of magnetic trains. It is assumed that this system is a hybrid system and it consists of electric and permanent magnet. For optimization of losses initially AC losses of magnetic levitation system are calculated. Linear model of levitation system as well as modeling ...
متن کاملTemperature Dependence of Magnetic Flux Drag Torque for a Single Grain YBa2Cu3O7 Superconductor
A modified close cycle helium gas cryogenic system was used to measure the flux drag torque acting on a free spinning disk magnet by a single grain YBCO superconductor. It was found that at low spinning speed ( less than 8 Hz ) and constant levitation height, the flux drag torque decreased with temperature which behavior is roughly similar to the temperature dependence of the reciprocal of crit...
متن کاملDiamagnetic levitation enhances growth of liquid bacterial cultures by increasing oxygen availability.
Diamagnetic levitation is a technique that uses a strong, spatially varying magnetic field to reproduce aspects of weightlessness, on the Earth. We used a superconducting magnet to levitate growing bacterial cultures for up to 18 h, to determine the effect of diamagnetic levitation on all phases of the bacterial growth cycle. We find that diamagnetic levitation increases the rate of population ...
متن کاملAccurate characteristics of Helium in nano-channels
This article describes an accurate subPico flowmeter bifurcatedin to liquid and gas flowrates less than 1mol/s for both MEMS/NEMS and cryogenic technology applications. The MEMS/NEMS are described as either two Gauges (instrument), or quartz fluctuating forks, even if the liquid or gas flows through an element, as well as cryogenic technology consisting of arrays of e...
متن کاملAccurate characteristics of Helium in nano-channels
This article describes an accurate subPico flowmeter bifurcatedin to liquid and gas flowrates less than 1mol/s for both MEMS/NEMS and cryogenic technology applications. The MEMS/NEMS are described as either two Gauges (instrument), or quartz fluctuating forks, even if the liquid or gas flows through an element, as well as cryogenic technology consisting of arrays of e...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physical review letters
دوره 77 23 شماره
صفحات -
تاریخ انتشار 1996