The stability of transmission lines relies on the health of the insulators, such as glass string insulators, which may occasionally flashover during an overvoltage. The likelihood of flashover increases notably when the glass insulator is wrapped by a wet contaminant layer. In this paper a study of the surface thermal profile of glass disc insulators insulation had been carried out for both clean and polluted surfaces. A finite-element simulation with time dependent model was carried out using COMSOL Multiphysics software. The variation of the insulator surface temperature with applied voltage as well as with pollution layer thickness is explained. The results illustrate the significant effect of pollution conductivity on heat propagate along the surface of the glass insulators with the increase higher voltages' magnitudes. Study of the aging level impact on a steady state thermal for glass insulation surface is also carried out.
منابع مشابه
Analysis of Flashover Voltages of Disc Type Insulator under Artificial Pollution Condition (TECHNICAL NOTE)
Through this paper work we have analyzed the effect of different contaminants on the flashover by creating artificial pollution condition, considering the natural condition where more than one salt as contaminant deposits on the surface of insulator at a time, under the wet condition that cause flow of highly leakage current, that leads to flashover. We choses the mixture of different salts, so...
متن کاملDesignation of an Indicator for flashover prediction of porcelain and glass insulators based on experimental tests.
Flashover of polluted insulators in contaminated areas is one of the most important factors influencing the operation of transmission and distribution lines and finally line outages. Therefore, it is essential to prevent and detect flashover in the insulators. Hence, utilizing the insulator status monitoring systems and predicting their functions have absorbed a lot of attention over the recent...
متن کاملImpact of Pollution Location on Time and Frequency Characteristics of Leakage Current of Porcelain Insulator String under Different Humidity and Contamination Severity
One of the important factors influencing outdoor insulators performance is pollution phenomenon. The pollution, especially during humidity condition, reduces superficial resistance of insulator and lead to a flow of Leakage Currents (LC) on the insulator surface, which may result in total flashover. The LC characteristics are affected by parameters such as nature and severity of pollution. Loca...
متن کاملEffects of Disc Insulator Type and Corona Ring on Electric Field and Voltage Distribution over 230-kV Insulator String by Numerical Method
Insulator strings with several material and profiles are very common in overhead transmission lines. However, the electric field and voltage distribution of insulator string is uneven which may easily lead to corona, insulators’ surface deterioration and even flashover. So the calculation of the electric field and voltage distribution along them is a very important factor in the operation time....
متن کاملAging Detection of Glass Disc Insulator by Using Infrared Camera
Suitable diagnostic techniques for outdoor glass insulators are important for ensuring the reliablilty and stability of power system. The possibility of insulator flash-over increases, especially when the insulator is covered by pollution layers or has an internal defect. In this paper, a new technique to detect the pollution level and invisible damage by measuring the surface temperature of gl...