Harmonic Distortion and Adc

نویسندگان

  • J. Halámek
  • M. Kasal
  • A. Cruz Serra
  • M. Villa
چکیده

The influence of different ADC nonlinearities on the measurement of ADC intermodulation products is discussed. It is shown that the amplitudes of harmonics and intermodulation products can be predicted only if the low order nonlinearity of the transfer curve is dominant and if a sufficient level of input noise or dither is used. 1 INTRODUCTION The ADC nonlinearities produce persistent sine waves error signals that affect more severely ADC performance than noise. The influence of some nonlinearities, such as quantization and DNL can be minimized by using dither or input noise that spread the spectrum of the corresponding error signals and so transfer the persistent sine waves power to noise. However, the influence of others, such as those of the low order nonlinearity of the transfer curve or of the dynamic behavior of the S/H circuit remains. The sine waves error signals can be divided into two groups: mixing products of the input signal (harmonics and intermodulation products) and mixing products between the input and the sampling frequency (spurious). The harmonics and intermodulation products could be considered as low order mixing products of the input produced by the nonlinear smoothed transfer curve. Being so not only the frequency, but also the amplitude could be predicted. The mth-order mixing product would change according to the mth-order law about its frequency and amplitude. If this is valid, the ADC's low order non-linearity could be described as in the case of analog circuits by intercept points or by the polynomial expression that describe the smoothed transfer curve [1,2]. Other attempts were made to compute the INL from harmonics amplitude [3]. In this paper we present numerical simulation and experimental results corresponding to preliminary work in this field. Our aim is to present our experience and open the discussion about the proper definition of harmonics and spurious. The main question is: when the signal changes only its frequency according to the mth-order law and its amplitude is random, is it an harmonic or a spurious component? 2 THEORY The smoothed ADC's transfer curve or the nonlinearity of an analog IC can be expressed by the low order polynomial expression y =a 0 + a 1 x + a 2 x 2 + a 3 x 3 + ....+a n x n , (1) where y is the equivalent the output signal, x the input signal and n the order of the circuit nonlinearity. Such …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fully-Efficient ADC Test Technique for ATE with Low Resolution Arbitrary Wave Generators

This paper presents a technique allowing the test of ADC harmonic distortions with only low-cost ATE. Contrary to a classical DSP-based test that requires an arbitrary wave generator (AWG) on the ATE with a resolution at least 2 bit higher than the ADC under test, the proposed solution permits to test ADCs using same resolution AWG. The method involves an initial learning phase in which the cha...

متن کامل

Static and Dynamic ADC Integral Nonlinearity Estimation

Integral nonlinearity (INL) should be main source of ADC's harmonic distortion. The basic question is importance of dynamic INL. There are still open questions how to describe dynamic INL and if the dynamic corrections of ADC have sense. Key-Words: ADC, testing, static, dynamic, INL, hysteresis

متن کامل

ADC Production Test Technique Using Low-Resolution Arbitrary Waveform Generator

Standard production test techniques for ADC require an ATE with an arbitrary waveform generator (AWG) with a resolution at least 2 bits higher than the ADC under test resolution. This requirement is a real issue for the new high-performance ADCs. This paper proposes a test solution that relaxes this constraint. The technique allows the test of ADC harmonic distortions using only low-cost ATE. T...

متن کامل

Achievable ADC Performance by Postcorrection Utilizing Dynamic Modeling of the Integral Nonlinearity

There is a need for a universal dynamic model of analog-to-digital converters (ADC’s) aimed for postcorrection. However, it is complicated to fully describe the properties of an ADC by a single model. An alternative is to split up the ADC model in different components, where each component has unique properties. In this paper, a model based on three components is used, and a performance analysi...

متن کامل

Signal Generator with Minimal Distortion for ADC Testing

The special generator of testing signal was designed for the frequency of 441.171 kHz. The generator consists of the special crystal oscillator and a high power amplifier. The frequency stability of the generator is in order of 10/day, the output power 1W, the value of SINAD is close to 120 dB and the total harmonic distortion under 170 dB by using of linear narrow-band filter.

متن کامل

A Novel 36-pulse rectifier with low kVA rate to reduce harmonic input current distortion

The increase in the number of pulses in multipulse rectifiers leads to a reduction in harmonic current distortion. But this increase in the number of pulses leads to an increase in kVA, cost, and complexity of the multi-pulse rectifiers. As a result, in industrial applications, 12-pulse rectifiers are mainly used due to their lightweight, simple transformers, and low kVA rate, and low cost. The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000