A quantitative method to measure human platelet chemotaxis using indium-111-oxine-labeled gel-filtered platelets.

نویسندگان

  • R W Lowenhaupt
  • E B Silberstein
  • M I Sperling
  • G Mayfield
چکیده

Human blood platelets have been shown to migrate directionally and specifically toward collagen in plasma in vitro. We have developed a new system to monitor this behavior using a linear 7-compartment chamber with 111In-oxine-labeled gel-filtered platelets. The compartments are separated by various Nuclepore and Millipore filter membranes. Radiolabeled platelets suspended in plasma are placed in the central compartment and the other compartments are filled with platelet-free plasma. When collagen is added to an end compartment, platelets migrate toward that end. The degree of this directed movement or chemotaxis can be measured by counting the radioactivity of the contents of each compartment and then comparing the counts from radiolabeled platelets that have moved to the end that holds the chemotactic inducer with those that have randomly migrated to the opposite end, containing only plasma. This assay system allows quantitative comparisons between the chemotaxis-inducing abilities of different substances and permits the study of soluble materials. Experiments to determine the optimal conditions for the procedure are reported, and the advantages of this new method for the investigation of platelet chemotaxis and the identification of chemotaxins are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Scintigraphic detection of carotid atherosclerosis with indium-111-labeled autologous platelets.

Using autologous platelets labeled with indium-111-oxine, we studied the localization of platelets on arterial lesions by radionuclide scintigraphy in 34 patients with suspected cerebrovascular disease. The imaging results were compared with the findings of contrast angiography in 23 patients, 16 of whom were receiving antiplatelet and/or anticoagulant drugs during the platelet imaging study. A...

متن کامل

Positive imaging of an inflammatory process at an arteriovenous access site with 111 Indium-labeled platelets.

Complications associated with the vascular access for hemodialysis represent one of the most important causes of morbidity among patients with renal replacement therapy. Early detection of arteriovenous fistula (AVF) dysfunction is of great interest. We present the case of a 70 year old woman who underwent 111In-oxine-labeled-platelet scintigraphy to evaluate thrombogenicity at 3 weeks and 3 mo...

متن کامل

Nuclide imaging of vascular graft-platelet interactions: comparison of indium excess and technetium subtraction techniques.

Indium-111-labeled platelet adherence to ePTFE thoracoabdominal vascular prostheses in a canine model (n = 10) was quantitated by (1) an indium-111 excess technique, contrasting graft radioactivity to that in a reference region, and (2) a technetium-99m subtraction technique, with radioactivity of circulating platelets eliminated by discounting background blood activity. Variation in graft thro...

متن کامل

Simplified and Efficient Labeling of Human Platelets in Plasma Using Indium-111-2-Mercaptopyridine-7V-Oxide: Preparation and Evaluation

The need for a gamma-emitting radioactive agent that will label platelets in plasma efficiently by a procedure that can be used uniformly in each laboratory is well recognized. A water soluble sodium salt of 2-Mercaptopyridine-A/-oxide (Merc) was evaluated that quantitatively chelated ln at a pH range of 0.7 to 7.4, and allowed greater than 80% incorporation of ln in platelets in plasma. This w...

متن کامل

Simplified and efficient labeling of human platelets in plasma using indium-111-2-mercaptopyridine-N-oxide: preparation and evaluation.

The need for a gamma-emitting radioactive agent that will label platelets in plasma efficiently by a procedure that can be used uniformly in each laboratory is well recognized. A water soluble sodium salt of 2-Mercaptopyridine-N-oxide (Merc) was evaluated that quantitatively chelated 111ln at a pH range of 0.7 to 7.4, and allowed greater than 80% incorporation of 111ln in platelets in plasma. T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Blood

دوره 60 6  شماره 

صفحات  -

تاریخ انتشار 1982