[A new method to quantify subjective aniseikonia].
نویسندگان
چکیده
PURPOSE To design subjective aniseikonia measuring criteria in order to quantify its value and to use it to the clinical practice. MATERIAL AND METHODS In order to carry out the aniseikonia measurements, a sinoptophore (Clement Clark) was used and two tests (one per eye of each patient) were performed. A viewfinder capable of measuring the difference in size between subjective images in both eyes was used and a percentage scale of ratio between 0 and 30%, with an accuracy of 1% was developed. An observational descriptive study was performed on 358 patients, and a complete ophthalmological examination also performed. The patients were divided in 3 groups: emmetropic patients, ametropic patients with non-progressive spectacles, and ametropic patients with hydrophilic contact lenses. RESULTS Of the 358 patients studied, 22.7% were men and 67.3% women. The average age was 38.3 (SD 17.3) years. 40.2% of the patients were emmetropic and 59.8% had some type of ametropia. When analyzing the refractive defect measured as the spherical equivalent we found a higher prevalence of myopia than hyperopia. The level of aniseikonia in the group of emmetropic patients was 1.6% (SD 3.11), in patients with glasses was 1.3% (SD 2.81), and in patients with contact lenses was 1.1% (SD 2.96). Comparing the results of aniseikonia in anisometropic and emmetropic patients, no statistically significant differences were found. CONCLUSION A simple method to quantify subjective aniseikonia, useful in clinical diagnosis has been designed.
منابع مشابه
Predicting refractive aniseikonia after cataract surgery in anisometropia.
PURPOSE To propose a comprehensive classification of anisometropia, a method to calculate the theoretical related aniseikonia (objective aniseikonia) and a purpose-designed eikonometer to measure aniseikonia psychophysically (subjective aniseikonia). SETTING University Hospital Antwerp, Department of Ophthalmology, Edegem, Belgium. METHODS The occurrence of anisometropia was evaluated in 26...
متن کاملSCIENTIFIC REPORT Aniseikonia associated with epiretinal membranes
Aims: To determine whether the computerised version of the new aniseikonia test (NAT) is a valid, reliable method to measure aniseikonia and establish whether aniseikonia occurs in patients with epiretinal membranes (ERM) with preserved good visual acuity. Methods: With a computerised version of the NAT, horizontal and vertical aniseikonia was measured in 16 individuals (mean 47 (SD 16.46) year...
متن کاملDifferences in tests of aniseikonia.
The New Aniseikonia Test (NAT), a hand-held direct-comparison test using red/green anaglyphs, has several potential advantages as a screener. We compared the validity of the NAT to that of the Space Eikonometer in three experiments: (1) aniseikonia was induced by calibrated size lenses in a double-blind study of 15 normal subjects; (2) habitual aniseikonia was measured with both instruments in ...
متن کاملDifferences in Tests of Aniseikonio
The New Aniseikonia Test (NAT), a hand-held direct-comparison test using red/green anaglyphs, has several potential advantages as a screener. We compared the validity of the NAT to that of the Space Eikonometer in three experiments: (1) aniseikonia was induced by calibrated size lenses in a doubleblind study of 15 normal subjects; (2) habitual aniseikonia was measured with both instruments in f...
متن کاملAniseikonia associated with epiretinal membranes.
AIMS To determine whether the computerised version of the new aniseikonia test (NAT) is a valid, reliable method to measure aniseikonia and establish whether aniseikonia occurs in patients with epiretinal membranes (ERM) with preserved good visual acuity. METHODS With a computerised version of the NAT, horizontal and vertical aniseikonia was measured in 16 individuals (mean 47 (SD 16.46) year...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archivos de la Sociedad Espanola de Oftalmologia
دوره 82 2 شماره
صفحات -
تاریخ انتشار 2007