Anterior-posterior impedance cardiography: a new approach to accurate, non-invasive monitoring of cardiac function.
نویسنده
چکیده
The conventional impedance cardiogram is a record of pulsatile changes in the electrical impedance of the chest with each heartbeat. The signal seems intuitively related to cardiac stroke volume. However doubts persist about the validity of stroke volume measurements based on electrical impedance. This paper presents a new electrical axis for impedance cardiography that is perpendicular to the conventional head-to-foot axis in an anterior-posterior direction. Dual chest and back electrodes are concentric, permitting tetrapolar technique. A relatively simple analytical model is developed, and this model is validated in a three-dimensional finite element model of current flow through the human chest. Three-dimensional simulations show predictable relationships between the fractional increase in anterior-posterior chest impedance and the ventricular ejection fraction (cardiac stroke volume/ventricular end-diastolic volume). Ejection fraction can be computed accurately with a roughly 30-fold increase in signal level compared to the conventional impedance cardiogram. Breathing causes only modest changes in the signal. When the axis of current flow is optimized, one can interpret the impedance changes during the cardiac cycle with greater confidence as noninvasive, beat-by-beat indicators of ventricular ejection fraction in a wide variety of clinical settings.
منابع مشابه
Impedance cardiography - Old method, new opportunities. Part I. Clinical applications.
Monitoring of cardiovascular hemodynamic changes requires a very expensive and highly specialized equipment and skilled medical personnel. Up to the present time, an inexpensive, non-invasive and easy-to-use method which, like Doppler echocardiography, magnetic resonance angiography or radionuclide imaging, would assess hemodynamics of the cardiovascular system was not available. A method known...
متن کاملAutomated non-invasive measurement of cardiac output: comparison of electrical bioimpedance and carbon dioxide rebreathing techniques.
Two commercial automated, non-invasive systems for estimation of cardiac output were evaluated. Values of cardiac output obtained by electrical bioimpedance cardiography (BoMed NCCOM3 machine) were compared with values derived from an indirect Fick technique that uses carbon dioxide rebreathing (Gould 9000 IV system) during 103 simultaneous measurements made at rest in 19 randomly selected subj...
متن کاملقلب نگاری امپدانسی روشی برای پایش غیرتهاجمی حجم ضربه ای: یک مطالعه ی مقدماتی
Abstract Background: Impedance cardiography (ICG) is a simple and inexpensive technique for non-invasive and continues measurement of stroke volume. Due to non-invasive nature, ICG is becoming increasingly used in research and clinical applications. With regard to lack of domestic impedance cardiograph and limited similar imported products in the country, an inexpensive and portable protot...
متن کاملEvaluation of Intra-aortic Balloon Counterpulsation Impact on Stroke Volume using a Non-invasive Technique: Impedance Cardiography
Evaluation of the haemodynamic state of patients with acute myocardial infarction (AMI) has always been a subject of interest for clinicians. The search of optimal methods and grounding of the indications for the monitoring of central hemodynamics conditioned the introduction of invasive methods for evaluation of hemodynamics into clinical practice in 1970. The method of intermittent thermodilu...
متن کاملCardiac output measured by transthoracic impedance cardiography at rest, during exercise and at various lung volumes.
1. Cardiac output measured by transthoracic impedance cardiography has been compared with simultaneous measurements made by the indirect Fick CO2 rebreathing method in nine adults and 14 children. All were healthy normal volunteers. Sixty-six comparisons were made at rest and during steady exercise at work loads up to 100 W. 2. Impedance measurements of cardiac output were consistently higher t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cardiovascular engineering
دوره 10 2 شماره
صفحات -
تاریخ انتشار 2010