Radiation Dose Reduction during Radial Cardiac Catheterization: Evaluation of a Dedicated Radial Angiography Absorption Shielding Drape

نویسندگان

  • Andrew Ertel
  • Jeffrey Nadelson
  • Adhir R. Shroff
  • Ranya Sweis
  • Dean Ferrera
  • Mladen I. Vidovich
چکیده

Objectives. Radiation scatter protection shield drapes have been designed with the goal of decreasing radiation dose to the operators during transfemoral catheterization. We sought to investigate the impact on operator radiation exposure of various shielding drapes specifically designed for the radial approach. Background. Radial access for cardiac catheterization has increased due to improved patient comfort and decreased bleeding complications. There are concerns for increased radiation exposure to patients and operators. Methods. Radiation doses to a simulated operator were measured with a RadCal Dosimeter in the cardiac catheterization laboratory. The mock patient was a 97.5 kg fission product phantom. Three lead-free drape designs were studied. The drapes were placed just proximal to the right wrist and extended medially to phantom's trunk. Simulated diagnostic coronary angiography included 6 minutes of fluoroscopy time and 32 seconds of cineangiography time at 4 standard angulated views (8 s each), both 15 frames/s. ANOVA with Bonferroni correction was used for statistical analysis. Results. All drape designs led to substantial reductions in operator radiation exposure compared to control (P < 0.0001). The greatest decrease in radiation exposure (72%) was with the L-shaped design. Conclusions. Dedicated radial shielding drapes decrease radiation exposure to the operator by up to 72% during simulated cardiac catheterization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reduction of operator radiation dose by a pelvic lead shield during cardiac catheterization by radial access: comparison with femoral access.

OBJECTIVES This study sought to determine the efficacy of patient pelvic lead shielding for the reduction of operator radiation exposure during cardiac catheterization via the radial access in comparison with the femoral access. BACKGROUND Cardiac catheterization via the radial access is associated with significantly increased radiation dose to the patient and the operator. Improvements in ra...

متن کامل

Radiation exposure in different cardiac catheterization procedures in cath lab.

BACKGROUND Interventional procedures render cardiologolists and their team members to high doses of radiations. This study was conducted to assess the radiation exposure in various cardiac catheterization procedures. METHODS This descriptive cross sectional study was conducted at the catheterization laboratory of Lady Reading Hospital Peshawar from November 2008 to December 2009. Patients wer...

متن کامل

Effect of Vascular Access Site Choice on Radiation Exposure During Coronary Angiography: The REVERE Trial (Randomized Evaluation of Vascular Entry Site and Radiation Exposure).

OBJECTIVES This study sought to perform a randomized noninferiority trial of radiation exposure during cardiac catheterization comparing femoral access (FA) with left radial access (LRA) and right radial access (RRA). BACKGROUND Increased radiation exposure with radial approach compared with femoral approach remains a controversial issue. METHODS This study randomized 1,493 patients undergo...

متن کامل

Comparison of the patient radiation exposure during coronary angiography and angioplasty procedures using trans-radial and trans-femoral access

INTRODUCTION Cardiac catheterization procedure through the trans-radial access (TRA) have shown many clinical advantages over the trans-femoral (TFA), but despite its advantages, there are serious concerns regarding higher possible radiation dose for the patients and operators in TRA. This study was planned to compare the patients' radiation dose associated with TRA and TFA during coronary angi...

متن کامل

Effect of a real-time radiation monitoring device on operator radiation exposure during cardiac catheterization: the radiation reduction during cardiac catheterization using real-time monitoring study.

BACKGROUND The Radiation Reduction During Cardiac Catheterization Using Real-Time Monitoring study sought to examine the effect of a radiation detection device that provides real-time operator dose reporting through auditory feedback (Bleeper Sv; Vertec Scientific Ltd; Berkshire, UK) on patient dose and operator exposure during cardiac catheterization. METHODS AND RESULTS Between January 2012...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2012  شماره 

صفحات  -

تاریخ انتشار 2012