Development of a multi-frequency laser for use in MALDI-TOFMS.
نویسندگان
چکیده
The application of a multi-frequency laser source for the use in matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOFMS) is described. An elliptically polarized beam of a Nd:YAG laser emitting at 355 nm (200 mJ) is focused into a Raman shifter, filled with high pressure hydrogen. As a result, numerous Raman lasers (including vibrational and rotational Raman emissions for hydrogen; 4155 and 587 cm(-1) shifts, respectively) were generated with a total power of approximately 100 mJ. Using this multi-frequency laser as an ionization source, methionine enkephalin (MW 573.7), angiotensin I (MW 1296.5) and oxidized insulin chain B (MW 3495.9) were examined, as model compounds using alpha-cyano-4-hydroxycinnamic acid (CHCA), sinapinic acid (SA) and activated charcoal as the matrix, respectively. As a result, the S/N ratios were improved when the multi-frequency laser was used, compared to the single light source of the Nd:YAG laser (355 nm), irrespective of the type of matrix used. This is because the multi-frequency laser provides multi-line for absorption, where the traditional N(2) laser only provides single wavelength (at 337 nm) for absorption.
منابع مشابه
Coupling thermal field-flow fractionation with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for the analysis of synthetic polymers.
Thermal field-flow fractionation (ThFFF) and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) have been coupled to yield a powerful combination of techniques for polymer analysis. Thermal FFF's high molecular weight (MW) selectivity and sensitivity to chemical composition are used to separate polydisperse polymers and polymer mixtures into the narrow po...
متن کاملA comparison of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry and surface plasmon resonance for genotyping of high-risk human papillomaviruses.
BACKGROUND Human papillomavirus (HPV) testing coupled with appropriate clinical management is associated with a significant decline in the rate of advanced cervical cancer and associated death. METHODS In this present study, we evaluated the performance of 2 new HPV genotyping methods, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) and surface plasm...
متن کاملSpecific recognition of DNA bulge structure by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.
This study reports a novel approach utilizing an octahedral CoII(HAPP)(TFA)2 reagent in the presence of H2O2 with analysis by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) to serve as an efficient probe for bulged DNA structures. Elucidation of DNA bulge-specific recognition pathways and cleavage mechanisms is demonstrated by characterization of bulg...
متن کاملExopeptidase degradation for the analysis of phosphorylation site in a mono-phosphorylated peptide with matrix-assisted laser desorption/ionization mass spectrometry.
The utility of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) coupled with a peptide ladder sequencing method employing exopeptidase degradation for the analysis of phosphorylation site in a mono-phosphorylated peptide is investigated. MALDI-TOFMS analysis of time-dependent exopeptidase digestion using carboxypeptidase W and aminopeptidase M of the mo...
متن کاملDevelopment of spray deposition/MALDI-TOFMS and its application to the rapid screening of hydrolysis products derived from nitrogen mustards.
A novel method for preparing samples for use in MALDI-TOFMS (matrix-assisted laser desorption ionization time-of-flight mass spectrometry) is described. Seven hydrolysis products derived from nitrogen mustards and CHCA (alpha-cyano-4-hydroxycinnamic acid) were selected as model compounds and the matrix, respectively. A capillary atomizer was used for evaporative and spray deposition of the samp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Talanta
دوره 68 3 شماره
صفحات -
تاریخ انتشار 2006