Peak pressures during manual ventilation.
نویسندگان
چکیده
INTRODUCTION Manual (bag) ventilation sometimes achieves better oxygenation than does a mechanical ventilator. We speculated that clinicians might generate very high airway pressure during manual ventilation (much higher than the pressure delivered by a mechanical ventilator), and that the high airway pressure causes alveolar recruitment and thus improves oxygenation. Such high pressure might injure alveoli in some patients. METHODS We tested the hypothesis that manual ventilation may involve substantially higher pressure than is delivered by a mechanical ventilator. We asked experienced respiratory therapists to manually ventilate a lung model that was set to represent several typical clinical scenarios. RESULTS We found that the peak airway pressure generated by the therapists was sometimes in excess of 100 cm H(2)O. CONCLUSIONS The high airway pressure during manual ventilation would be considered extreme in the context of conventional mechanical ventilation, which raises questions about whether manual ventilation causes barotrauma.
منابع مشابه
Manual ventilation and open suction procedures contribute to negative pressures in a mechanical lung model
INTRODUCTION Removal of pulmonary secretions in mechanically ventilated patients usually requires suction with closed catheter systems or flexible bronchoscopes. Manual ventilation is occasionally performed during such procedures if clinicians suspect inadequate ventilation. Suctioning can also be performed with the ventilator entirely disconnected from the endotracheal tube (ETT). The aim of t...
متن کاملNeonatal resuscitation 3: manometer use in a model of face mask ventilation.
BACKGROUND Adequate ventilation is the key to successful neonatal resuscitation. Positive pressure ventilation (PPV) is initiated with manual ventilation devices via face masks. These devices may be used with a manometer to measure airway pressures delivered. The expiratory tidal volume measured at the mask (V(TE(mask))) is a good estimate of the tidal volume delivered during simulated neonatal...
متن کاملEvaluation of an automated endotracheal tube cuff controller during simulated mechanical ventilation.
BACKGROUND Maintaining endotracheal tube cuff pressure within a narrow range is an important factor in patient care. The goal of this study was to evaluate the IntelliCuff against the manual technique for maintaining cuff pressure during simulated mechanical ventilation with and without movement. METHODS The IntelliCuff was compared to the manual technique of a manometer and syringe. Two inde...
متن کاملNeonatal resuscitation 2: an evaluation of manual ventilation devices and face masks.
BACKGROUND The key to successful neonatal resuscitation is effective ventilation. Little evidence exists to guide clinicians in their choice of manual ventilation device or face mask. The expiratory tidal volume measured at the mask (V(TE(mask))) is a good estimate of the tidal volume delivered during simulated neonatal resuscitation. AIM To compare the efficacy of (a) the Laerdal infant resu...
متن کاملComparison of efficacy of three devices of manual positive pressure ventilation: a mannequin-based study
BACKGROUND We compared the efficacy of and consistency in manual ventilation by trained healthcare professionals using three devices: self-inflating bag, flow-inflating bag, and T-piece resuscitator. METHODS Prospective analytical study at a level III Neonatal unit of a tertiary care hospital. Forty participants (consultants, postgraduates, interns, and neonatal nurses - 10 each) manually ven...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory care
دوره 50 3 شماره
صفحات -
تاریخ انتشار 2005