Assessing intracranial vascular compliance using dynamic arterial spin labeling

نویسندگان

  • Lirong Yan
  • Collin Y. Liu
  • Robert X. Smith
  • Mayank A. Jog
  • Michael Langham
  • Kate Krasileva
  • Yufen Chen
  • John M. Ringman
  • Danny J. J. Wang
چکیده

Vascular compliance (VC) is an important marker for a number of cardiovascular diseases and dementia, which is typically assessed in the central and peripheral arteries indirectly by quantifying pulse wave velocity (PWV), and/or pulse pressure waveform. To date, very few methods are available for the quantification of intracranial VC. In the present study, a novel MRI technique for in-vivo assessment of intracranial VC was introduced, where dynamic arterial spin labeling (ASL) scans were synchronized with the systolic and diastolic phases of the cardiac cycle. VC is defined as the ratio of change in arterial cerebral blood volume (ΔCBV) and change in arterial pressure (ΔBP). Intracranial VC was assessed in different vascular components using the proposed dynamic ASL method. Our results show that VC mainly occurs in large arteries, and gradually decreases in small arteries and arterioles. The comparison of intracranial VC between young and elderly subjects shows that aging is accompanied by a reduction of intracranial VC, in good agreement with the literature. Furthermore, a positive association between intracranial VC and cerebral perfusion measured using pseudo-continuous ASL with 3D GRASE MRI was observed independent of aging effects, suggesting loss of VC is associated with a decline in perfusion. Finally, a significant positive correlation between intracranial and central (aortic arch) VC was observed using an ungated phase-contrast 1D projection PWV technique. The proposed dynamic ASL method offers a promising approach for assessing intracranial VC in a range of cardiovascular diseases and dementia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Temporal and Spatial Variances in Arterial Spin-Labeling Are Inversely Related to Large-Artery Blood Velocity.

BACKGROUND AND PURPOSE The relationship between extracranial large-artery characteristics and arterial spin-labeling MR imaging may influence the quality of arterial spin-labeling-CBF images for older adults with and without vascular pathology. We hypothesized that extracranial arterial blood velocity can explain between-person differences in arterial spin-labeling data systematically across cl...

متن کامل

Quantitative assessment of mixed cerebral vascular territory supply with vessel encoded arterial spin labeling MRI.

BACKGROUND AND PURPOSE Recent advances in arterial spin labeling MRI have permitted noninvasive evaluation of vascular territories. In the present study, we quantitatively assess mixing of internal carotid and basilar artery blood through cerebrovascular anastomoses using vessel-encoded arterial spin labeling and a new postprocessing method. METHODS Vessel-encoded arterial spin labeling was u...

متن کامل

A Two-Stage Model for In Vivo Assessment of Brain Tumor Perfusion and Abnormal Vascular Structure Using Arterial Spin Labeling

The ability to assess brain tumor perfusion and abnormalities in the vascular structure in vivo could provide significant benefits in terms of lesion diagnosis and assessment of treatment response. Arterial spin labeling (ASL) has emerged as an increasingly viable methodology for non-invasive assessment of perfusion. Although kinetic models have been developed to describe perfusion in healthy t...

متن کامل

Noninvasive assessment of arterial compliance of human cerebral arteries with short inversion time arterial spin labeling

A noninvasive method of assessing cerebral arterial compliance (AC) is introduced in which arterial spin labeling (ASL) is used to measure changes in arterial blood volume (aBV) occurring within the cardiac cycle. Short inversion time pulsed ASL (PASL) was performed in healthy volunteers with inversion times ranging from 250 to 850 ms. A model of the arterial input function was used to obtain t...

متن کامل

Assessment of intracranial collateral flow by using dynamic arterial spin labeling MRA and transcranial color-coded duplex ultrasound.

BACKGROUND AND PURPOSE To evaluate the potential of a new dynamic MRA sequence (DynAngio) based on arterial spin labeling for the assessment of intracranial collateral flow. METHODS Twelve patients with unilateral internal carotid artery obstruction were investigated. Different patterns of collateral flow were compared between DynAngio, transcranial color-coded duplex ultrasound, and time-of-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • NeuroImage

دوره 124 Pt A  شماره 

صفحات  -

تاریخ انتشار 2016