Initial feasibility investigation of the v-gel airway: an anatomically designed supraglottic airway device for use in companion animal veterinary anaesthesia.

نویسنده

  • Ivan R Crotaz
چکیده

I would like to report a feasibility study into the use, in small animal anaesthesia, of a supraglottic airway device, designed for veterinary use. Rabbit anaesthesia carries a higher anaesthetic risk compared with anaesthesia in dogs and cats (Brodbelt et al. 2008). One reason may be that endotracheal intubation can be difficult to perform in rabbits, because they have a narrow pharyngeal inlet, a small larynx and minimal pharyngeal and laryngeal visibility during oral examination. As a result, some general practitioners use face masks in preference, which may not preserve the airway, and makes controlled ventilation difficult. Repeated intubation attempts in rabbits might cause laryngeal trauma, which could then result in airway obstruction following extubation. The use of a well designed supraglottic airway device (or ‘laryngeal mask’) should make airway management easier for practitioners (Smith et al. 2004). A number of studies have been carried out using laryngeal masks for rabbit anaesthesia, (Smith et al. 2004; Yuri et al. 2007) including one that employed human paediatric devices (Kazakos et al. 2007). Other species might also benefit from changes to airway management, in particular the cat, as endotracheal intubation has been associated with increased risk of anaesthetic death (Brodbelt et al. 2008). The i-gel (Intersurgical, UK) is a novel human supraglottic airway device developed by Dr. M.A. Nasir (Levitan & Kinkle 2005). The author has carried out a cadaver study in collaboration with Dr. Nasir. The purpose of this study was to investigate the feasibility of using a noninflatable supraglottic airway device, (v-gel) that would consistently self position over the laryngeal inlet in small companion animal patients such as rabbits and cats and small dogs. Post-mortem work was carried out on various companion animal cadavers. All owners gave informed consent. Neck dissections of seven cats and five rabbits and four dogs (below 10 kg body weight) were performed. Using the size 1 i-gel device as a starting point, each device was placed through the mouth into the pharyngeal area. Once each device had been inserted, a dissection was performed from the ventral skin surface into the laryngeal and pharyngeal areas. The position of each device was observed

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries

Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...

متن کامل

Initial anatomic investigations of the I-gel airway: a novel supraglottic airway without inflatable cuff.

The I-gel airway is a novel supraglottic airway that uses an anatomically designed mask made of a gel-like thermoplastic elastomer. We studied the positioning and mechanics of this new device in 65 non-embalmed cadavers with 73 endoscopies (eight had repeat insertion), 16 neck dissections, and six neck radiographs. A full view of the glottis (percentage of glottic opening score 100%) occurred i...

متن کامل

Evaluation of four airway training manikins as patient simulators for the insertion of eight types of supraglottic airway devices.

We evaluated the performance of four currently available manikins: Airway Management Trainer (Ambu, UK), Airway Trainer (Laerdal, Norway), Airsim (Trucorp, Ireland), 'Bill 1' (VBM, Germany), with eight supraglottic airway devices: Airway Management Device, Cobra Perilaryngeal Airway, Combitube, i-Gel, Laryngeal Tube, Laryngeal Tube Disposable, Laryngeal Tube Suction II and Streamlined Liner of ...

متن کامل

A randomised trial to compare i-gel and ProSeal™ laryngeal mask airway for airway management in paediatric patients

BACKGROUND AND AIMS i-gel™ is a newer supraglottic airway device with a unique non-inflatable cuff. We aimed to compare i-gel™ with ProSeal™ laryngeal mask airway (PLMA™) in children scheduled for surgery under general anaesthesia (GA) with controlled ventilation. METHODS This prospective, randomised controlled study was conducted in 100 surgical patients, aged 2-6 years of American Society o...

متن کامل

Case Report of an open Neck Procedure Complication Associated with Laryngeal Mask Airway Use

Introduction: The laryngeal mask airway (LMA) is a safe method to establish airway control during general anaesthesia. In otolaryngology surgery, the use of a LMA is well established in ear surgery; however, the use of a LMA during open neck procedures remains controversial. We report a case in which the pharyngeal distortion by the LMA cuff resulted in an iatrogenic complication.   Case Report...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Veterinary anaesthesia and analgesia

دوره 37 6  شماره 

صفحات  -

تاریخ انتشار 2010