Effect of tooth displacement and vibration on frictional force and stick-slip phenomenon in conventional brackets: a preliminary in vitro mechanical analysis.

نویسندگان

  • Yu-Jin Seo
  • Bum-Soon Lim
  • Young Guk Park
  • Il-Hyung Yang
  • Seok-Joon Ahn
  • Tae-Woo Kim
  • Seung-Hak Baek
چکیده

OBJECTIVE To evaluate the effects of tooth displacement and vibration on frictional force and stick-slip phenomenon (SSP) when conventional brackets were used with a levelling/alignment wire. MATERIALS AND METHODS The samples consisted of six groups (n = 10 per group) with combinations of tooth displacement (2mm lingual displacement [LD], 2mm gingival displacement [GD], and no displacement [control]) and vibration conditions (absence and presence at 30 Hz and 0.25 N). A stereolithographically made typodont system was used with conventional brackets and elastomeric ligatures. After application of artificial saliva, static/kinetic frictional forces (SFF/KFF) and frequency/amplitude of SSP were measured while drawing a 0.018-inch copper nickel-titanium (Cu-NiTi) archwire at a speed of 0.5mm/min for 5 minutes at 36.5 degree celsius. Two-way analysis of variance and independent t-test were performed. RESULTS Tooth displacement increased SFF and KFF (control < LD < GD, all P < 0.001) and reduced SSP frequency (control > [LD, GD], P < 0.01). Vibration reduced SFF, KFF, and SSP amplitude in the control group (P < 0.05, P < 0.05, and P < 0.001, respectively), but not in the LD and GD groups. SSP frequency was increased by vibration in the control, LD, and GD groups (all P < 0.001), and it was lower in the LD and GD groups than in the control group (P < 0.01). CONCLUSIONS When conventional brackets and a 0.018-inch Cu-NiTi archwire were used in the tooth displacement conditions (LD and GD), vibration did not significantly reduce SFF, KFF, or SSP amplitude.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of tooth displacement and vibration on frictional force and stick-slip phenomenon in conventional brackets: a preliminary in vitro mechanical analysis

Objective: To evaluate the effects of tooth displacement and vibration on frictional force and stickslip phenomenon (SSP) when conventional brackets were used with a levelling/alignment wire. Materials and Methods: The samples consisted of six groups (n = 10 per group) with combinations of tooth displacement (2 mm lingual displacement [LD], 2 mm gingival displacement [GD], and no displacement [...

متن کامل

Effect of self-ligating bracket type and vibration on frictional force and stick-slip phenomenon in diverse tooth displacement conditions: an in vitro mechanical analysis.

OBJECTIVE To evaluate the effects of self-ligating bracket (SLB) type and vibration on frictional force and stick-slip phenomenon (SSP) in diverse tooth displacement conditions when a levelling/alignment wire was drawn. MATERIALS AND METHODS A total of 16 groups were tested (n = 10/group): Two types of SLBs [active SLB (ASLB, In-Ovation R) and passive SLB (PSLB, Damon Q)]; vibration (30 Hz an...

متن کامل

Evaluation of the Effect of an Experimental Herbal versus Fluoridated Mouthwash on Frictional Resistance and Surface Roughness between Orthodontic Brackets and Two Types of Archwire: In Vitro Study

Introduction: The present study aimed to evaluate an experimental herbal mouthwash, as compared to sodium fluoride mouthwash on the frictional resistance and surface roughness between brackets and two rectangular archwire types. Methods: A total of 60 premolar׳s brackets engaged with 0.019×0.025 archwires made of stainless steel and nickel-titanium alloys were used in this study. The samples we...

متن کامل

Frictional property comparisons of conventional and self-ligating lingual brackets according to tooth displacement during initial leveling and alignment: an in vitro mechanical study

OBJECTIVE We evaluated the effects of tooth displacement on frictional force when conventional ligating lingual brackets (CL-LBs), CL-LBs with a narrow bracket width, and self-ligating lingual brackets (SL-LBs) were used with initial leveling and alignment wires. METHODS CL-LBs (7th Generation), CL-LBs with a narrow bracket width (STb), and SL-LBs (In-Ovation L) were tested under three tooth ...

متن کامل

Finite Element Analysis and Experimental Investigation on the Conventional and Vibration Assisted Drilling

In this research, finite element analysis of the conventional drilling and vibration assisted drilling is carried out. The ABAQUS software is employed for FE analysis. The Johnson-Cook models for both plastic deformation and damage are employed for FE simulation.The results of the FE analysis are then verified with experimental results in both conventional and vibration assisted drilling on Al ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of orthodontics

دوره 37 2  شماره 

صفحات  -

تاریخ انتشار 2015