Schlemm’s Canal and Trabecular Meshwork in Eyes with Primary Open Angle Glaucoma: A Comparative Study Using High-Frequency Ultrasound Biomicroscopy
نویسندگان
چکیده
We investigated in vivo changes in Schlemm's canal and the trabecular meshwork in eyes with primary open angle glaucoma (POAG). Relationships between Schlemm's canal diameter, trabecular meshwork thickness, and intraocular pressure (IOP) were examined. Forty POAG patients and 40 normal individuals underwent 80-MHz Ultrasound Biomicroscopy examinations. The Schlemm's canal and trabecular meshwork were imaged in superior, inferior, nasal and temporal regions. Normal individuals had an observable Schlemm's canal in 80.3% of sections, a meridional canal diameter of 233.0±34.5 μm, a coronal diameter of 44.5±12.6 μm and a trabecular meshwork thickness of 103.9±11.1 μm, in POAG patients, Schlemm's canal was observable in 53.1% of sections, a meridional canal diameter of 195.6±31.3 μm, a coronal diameter of 35.7±8.0 μm, and a trabecular meshwork thickness of 88.3±13.2 μm, which significantly differed from normal (both p <0.001). Coronal canal diameter (r = -0.623, p < 0.001) and trabecular meshwork thickness (r = -0.663, p < 0.001) were negatively correlated with IOP, but meridional canal diameter was not (r = -0.160, p = 0.156). Schlemm's canal was observable in 50.5% and 56.6% of POAG patients with normal (<21 mmHg) and elevated (>21 mmHg) IOP, respectively (χ = 1.159, p = 0.282). Coronal canal diameter was significantly lower in the elevated IOP group (32.6±4.9 μm) than in the normal IOP group (35.7±8.0 μm, p < 0.001). This was also true of trabecular meshwork thickness (81.9±10.0 μm vs. 97.1±12.0 μm, p < 0.001). In conclusion, eyes with POAG had fewer sections with an observable Schlemm's canal. Canal diameter and trabecular meshwork thickness were also lower than normal in POAG patients. Schlemm's canal coronal diameter and trabecular meshwork thickness were negatively correlated with IOP.
منابع مشابه
Aqueous Humor Levels of Soluble Fas and Fas-ligand in Patients with Primary Open Angle and Pseudoex-foliation Glaucoma
Background: Glaucoma is one of the most common causes of blindness and is usually associated with elevated intraocular pressure. In patients with primary open angle glau-coma the number of trabecular meshwork cells is decreased. Death of the trabecular meshwork cells may be a result of apoptosis. Objective: To investigate the aqueous humor levels of soluble Fas (sFas) and Fas-Ligand (sFasL) in ...
متن کاملGlaucoma surgery and aqueous outflow: how does nonpenetrating glaucoma surgery work?
B LEBS. SHALLOW CHAMBERS. Bleb leaks. Flat chambers. Dellen. Blebitis. No bleb. Late failure. Hypotony. Choroidal effusions. Maculopathy. Is there a better way? If the problem is in the meshwork, why do we cut a hole in the eye? Viscocanalostomy and deep sclerectomy are surgical procedures for glaucoma that have been designed to avoid some of the complications of conventional glaucoma surgery. ...
متن کاملLocalization of the stress proteins alpha B-crystallin and trabecular meshwork inducible glucocorticoid response protein in normal and glaucomatous trabecular meshwork.
PURPOSE To examine the differential staining of two potential stress-response markers, alpha B-crystallin and the trabecular meshwork inducible glucocorticoid response protein (TIGR), in meshwork from normal and glaucomatous human eyes. METHODS Trabecular meshwork from 35 eyes from 23 donors with either primary open-angle glaucoma, pseudoexfoliative glaucoma, or low-tension glaucoma, and from...
متن کاملMathematical Modelling of Flow in Schlemm’s Canal and Its Influence on Primary Open Angle Glaucoma
POAG (Primary Open Angle Glaucoma) is a major cause of blindness. This normally occurs when the IOP (intraocular pressure) increases. High pressure can be caused by an imbalance in the production and drainage of fluid (aqueous humour, AH) in the eye. AH is continually being produced but sometimes cannot be drained because of improperly functioning drainage channels (trabecular meshwork, TM). A ...
متن کاملExcess Fibronectin Accumulation in the Trabecular Meshwork: A Potential Mechanism for Increasing Aqueous Outflow Resistance
Purpose:Substantial evidence indicates that extracellular matrix accumulation in trabecular meshwork (TM) is associated with aqueous outflow resistance. The purpose of this study is to determine whether excess fibronectin (FN) accumulation in TM contributes to outflow resistance by downregulating synthesis of FN overexpression by the TM cells in primary open angle glaucoma. Methods:Cryosections...
متن کامل