Percutaneous closure of mitral paravalvular leak.
نویسنده
چکیده
Paravalvular leak (PVL) is a complication observed in patients after prosthetic valve replacement. The incidence of PVL is estimated as 2-3%. The cause of PVL may be paravalvular infection, suture continuity disruption, damage of tissues around the annulus or limitation of disc mobility by thrombus or vegetation. The preferable method of treatment of PVL is surgery. Recently, percutaneous closure of PVL became an alternative method. We present a case of successfully completed percutaneous closure of PVL with the use of Amplatzer occluder device in a patient with mitral PVL.
منابع مشابه
Percutaneous retrograde transfemoral closure of mitral paravalvular leak in 3 patients without construction of an arteriovenous wire loop.
Percutaneous closure of paravalvular leaks has emerged as an alternative to repeated surgeries. Different percutaneous techniques and various devices have been used, off-label, for paravalvular leak closure. For mitral leaks, antegrade transseptal, retrograde transfemoral, and retrograde transapical techniques have been developed. In the antegrade transseptal approach, an arteriovenous guidewir...
متن کاملBioprosthetic leaflet erosion after percutaneous mitral paravalvular leak closure.
Davis nline ranscatheter closure of prosthetic paravalvular eaks is increasingly performed at experienced enters (1–3). The lack of devices dedicated to aravalvular leak closure has not deterred the ff-label use of various occluder devices. These mages illustrate the potential complexity of ranscatheter paravalvular leak repair with the eed for additional occluder placement, and the evelopment ...
متن کاملMechanical interference between a closure device and the rigid stent of mitral bioprosthesis: a mechanism for closure device late dislodgement.
: We report here the mechanical interference between mitral bioprostheses and devices currently adopted for percutaneous paravalvular leak closure as a possible cause for late dislodgement and embolization of successfully implanted and apparently stable closure devices.The images included in this study demonstrate that the topographical relationship of the target leak with the bioprosthetic val...
متن کاملParavalvular leak closure with the Amplatzer Vascular Plug III device: immediate and short-term results.
INTRODUCTION AND OBJECTIVES Percutaneous paravalvular leak closure is a complex procedure with varying success rates; the lack of closure devices specifically designed for this purpose has hampered this technique. The characteristics of the Amplatzer Vascular Plug III appear to be well suited for paravalvular leak closures; however, the available data are limited to case reports or small series...
متن کاملFailed percutaneous closure of a mitral prosthesis paravalvular leak.
A 77-year-old man who had a mechanical prosthetic mitral valve and aortic valve implanted in 1993 presented dyspnea and anemia, and was diagnosed of mitral prosthesis paravalvular leak. The patient was considered at high operative risk owing to his age, severe pulmonary hypertension, chronic renal failure, and previous cardiac surgery. Surgical treatment in his reference hospital was therefore ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of interventional cardiology
دوره 16 2 شماره
صفحات -
تاریخ انتشار 2003