Multicenter evaluation of the BACTEC MGIT 960 system for recovery of mycobacteria.

نویسندگان

  • B A Hanna
  • A Ebrahimzadeh
  • L B Elliott
  • M A Morgan
  • S M Novak
  • S Rusch-Gerdes
  • M Acio
  • D F Dunbar
  • T M Holmes
  • C H Rexer
  • C Savthyakumar
  • A M Vannier
چکیده

We evaluated the BACTEC MGIT 960 system, which is a fully automated, noninvasive system for the growth and detection of mycobacteria with a capacity to incubate and continuously monitor 960 7-ml culture tubes. We studied 3,330 specimens, 2,210 respiratory and 1,120 nonrespiratory specimens, collected from 2,346 patients treated at six sites. Processed specimens were inoculated into the BACTEC MGIT 960 and BACTEC 460 TB systems, as well as onto Lowenstein-Jensen slants and Middlebrook 7H11/7H11 selective plates. From all culture systems, a total of 362 isolates of mycobacteria were recovered; these were recovered from 353 specimens collected from 247 patients. The greatest number of isolates of mycobacteria (289, or 80% of the 362 isolates) was recovered with the BACTEC MGIT 960, followed by the BACTEC 460 TB (271, or 75%) and solid media (250, or 69%). From all culture systems a total of 132 isolates of Mycobacterium tuberculosis complex were recovered. The greatest number of isolates of M. tuberculosis complex was recovered when liquid medium was combined with conventional solid media; the number recovered with BACTEC 460 TB plus solid media was 128 (97%), that recovered with BACTEC MGIT 960 plus solid media was 121 (92%), that recovered with BACTEC 460 TB was 119 (90%) and that recovered with all solid media combined was 105 (79%). The recovery with BACTEC MGIT 960 alone was 102 (77%). The mean times to detection (TTD) for M. tuberculosis complex were 14.4 days for BACTEC MGIT, 15.2 days for BACTEC 460 TB, and 24.1 days for solid media. The numbers of isolates of Mycobacterium avium complex (MAC) recovered were 172 (100%) for all systems, 147 (85%) for BACTEC MGIT 960, 123 (72%) for BACTEC 460 TB, and 106 (62%) for all solid media combined. The TTD for MAC in each system were 10.0 days for BACTEC MGIT 960, 10.4 days for BACTEC 460 TB, and 25.9 days for solid media. Breakthrough contamination rates (percentages of isolates) for each of the systems were 8.1% for BACTEC MGIT 960, 4.9% for BACTEC 460 TB, and 21.1% for all solid media combined.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multicenter evaluation of fully automated BACTEC Mycobacteria Growth Indicator Tube 960 system for susceptibility testing of Mycobacterium tuberculosis.

The reliability of the BACTEC Mycobacteria Growth Indicator Tube (MGIT) 960 system for testing of Mycobacterium tuberculosis susceptibility to the three front-line drugs (isoniazid [INH], rifampin [RIF], and ethambutol [EMB]) plus streptomycin (STR) was compared to that of the BACTEC 460 TB system. The proportion method was used to resolve discrepant results by an independent arbiter. One hundr...

متن کامل

Evaluation of BACTEC MGIT 960 and BACTEC 460TB systems for recovery of mycobacteria from clinical specimens of a university hospital with low incidence of tuberculosis.

Clinical samples obtained over a period of 8 months (n = 2,624) were processed in parallel with the BACTEC 460TB system, with the MGIT 960 system, and in Löwenstein-Jensen (LJ) medium, resulting in the recovery of 127 mycobacteria. Recovery rates in combinations of the BACTEC 460TB or MGIT 960 system with LJ were, respectively, 94.7 and 94.7% for Mycobacterium tuberculosis complex (n = 57) and ...

متن کامل

Comparison of the BACTEC MGIT 960 and ESP culture system II for growth and detection of mycobacteria.

The performances of two continuously monitoring mycobacterial culture systems-ESP Culture System II (ESP II; Trek Diagnostics, Inc. , Westlake, Ohio) and BACTEC MGIT 960 (BD Biosciences, Sparks, Md. )-were compared. In addition to both liquid media, all specimens were plated onto Middlebrook 7H11/7H11 selective agar. A total of 3, 151 specimens of all types (56.3% were respiratory specimens) we...

متن کامل

Use of the BACTEC Mycobacteria Growth Indicator Tube 960 automated system for recovery of Mycobacteria from 9,558 extrapulmonary specimens, including urine samples.

The BACTEC Mycobacteria Growth Indicator Tube 960 (MGIT 960) system was applied for recovery of mycobacteria from extrapulmonary specimens and compared with solid media (Löwenstein-Jensen and Stonebrink). A total of 9,558 specimens were investigated, comprising 3,074 body fluids, 1,878 tissues, and 2,069 urine samples, from which the recovery of mycobacteria was not yet established for MGIT 960...

متن کامل

Comparison of recoveries of mycobacterium tuberculosis using the automated BACTEC MGIT 960 system, the BACTEC 460 TB system, and Löwenstein-Jensen medium.

Using two different liquid media and one conventional solid medium, a total of 57 mycobacterial isolates (Mycobacterium tuberculosis, n = 55; nontuberculous mycobacteria, n = 2) were recovered from 377 clinical specimens. The rates of recovery of M. tuberculosis were 96. 4% with the BACTEC MGIT 960 liquid medium, 92.7% with BACTEC 12B liquid medium, and 81.8% with the Löwenstein-Jensen (LJ) med...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 37 3  شماره 

صفحات  -

تاریخ انتشار 1999