SU-E-T-479: Skin Dose from Flattening Filter Free Beams: A Monte Carlo Investigation.
نویسندگان
چکیده
PURPOSE Flattening filter free (FFF) beams in radiotherapy have advantages such as shorter treatment delivery time and lower out-of-field dose compared with conventional flattened beams. This study investigates in detail the skin dose induced by FFF beams from a TrueBeam accelerator (Varian Medical Systems, Palo Alto, CA) using Monte Carlo method. METHODS Phase space files generated using real geometry of a TrueBeam accelerator above the jaws, were used as the input radiation source files in beam simulation for various field sizes using BEAMnrc. Phase space files for various field sizes were generated at the phantom surface. DOSXYZnrc was used for dose calculations in phantom and in patient using the generated phase space files as source input files. RESULTS The calculated percentage depth dose curves and profiles in water agreed with measurements within ± 2% for the high dose region and ±2 mm in the penumbra. The peak fluence of a 6 MV FFF beam with the same electron beam incident on the target is about 3 times that of a flattened beam . The mean energy of a 6 MV FFF beam is 0.92-0.95 MeV while it is 1.18-1.30 MeV for the flattened beam. Due to the mean energy difference, the dose in a 6 MV FFF beam is about 6% (of the maximum dose, or 12% of local dose) higher at depth of 1 mm compared with a flattened beam. CONCLUSIONS Due to the lower mean photon energy, in an FFF beam the surface (skin) dose is slightly higher compared to the conventional flattened beam of the same field size.
منابع مشابه
Enhancement of the Dose on 12 MV Linac with Free Flattening Filter Mode
Purpose: In the last years, some studies investigated dosimetric benefits of a free flattening filter for the photon mode in the radiotherapy field. This study aims to provide a theoretical study published and analysis of basic dosimetric properties for a Saturne 43 Linac head to implement free flattening filter beams clinically. Material and Methods: Thi...
متن کاملMonte Carlo Study of Unflattened Photon Beams Shaped by Multileaf Collimator
Introduction: This study investigates basic dosimetric properties of unflattened 6 MV photon beam shaped by multileaf collimator and compares them with those of flattened beams.Materials and Methods: Monte Carlo simulation model using BEAM code was developed for a 6MV photon beam based on Varian Clinic 600 unique performance linac operated with and without a flattening filter in beam line. Dosi...
متن کاملInvestigation of Neutron Contamination of Flattening Filter and Flattening Filter-Free 10-MV Photon Beams in Elekta InfinityTM Accelerator
Introduction: This study aimed to measure the neutron contamination of flattening filter (FF) and flattening filter-free (FFF) 10-MV photon beams delivered by the Elekta InfinityTM accelerator. Material and Methods: The photoneutron spectrum produced by the Linac head was evaluated using a Monte Carlo (MC) simulation. The geometry ...
متن کاملAdvantages and disadvantages of removed flattening filter Linac: A Monte Carlo study on full quantitative dosimetric data of 18 MV-Varian Linac
Introduction: During intensity modulated radiation therapy (IMRT) technique, theoretically, presence of flattening filter (FF) across the beamline of clinical linear accelerator (linac) is not essential to obtain uniform lateral profiles due to intensity modulation of photon beams by multileaf collimators (MLCs). The aim of this study was to investigate the dosimetrical propert...
متن کاملAccess to the Published Version May Require Journal Subscription. Published with Permission From: American Association of Physicists in Medicine Prediction of Stopping-power Ratios in Flattening-filter Free Beams
This is an author produced version of a paper published in Medical Physics. This paper has been peer-reviewed but does not include the final publisher proof-corrections or journal pagination. "Prediction of stopping-power ratios in flattening-filter free beams." Abstract 25 Purpose: In recent years, there has been an increasing interest in flattening-filter free (FFF) beams. However, since the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 39 6Part17 شماره
صفحات -
تاریخ انتشار 2012