Degree of conversion of resin composite cured by light through a translucent fiber posts
نویسنده
چکیده
PURPOSE This study evaluated the depth of cure of resin composite cured by light through a translucent fiber post. MATERIALS AND METHODS The opaque plastic tubes in various lengths of 2, 4, 6, 8, 10, 12, 14 mm. were filled with resin composite in which two different translucent fiber posts were inserted into the center and photo-polymerized for 40 seconds. The degree of conversion of the cured composite at bottom surface were examined using Fourier transform infrared attenuated total reflection spectrometer (FTIR/ATR) at 0.1, 0.5 and 1.0 mm apart from the post surface. RESULTS The degree of conversion of the 0.1 mm, 0.5 mm, 1.0 mm apart from the post surface was highest at the 2 mm level and continuously decreased when the distance from the light source was increased and drastically decreased when the depth from the top of the post was greater than 4-6 mm. For each level, the highest degree of conversion was at 0.1 mm from the post surface and decreased continuously when the distance apart from the post surface was increased. CONCLUSION The quantity of light transmission depends on the type of post and the light transmission capability of the post, especially after 4-6 mm depth and the area further apart from the post surface, are insufficient for clinical light activation of resin composite.
منابع مشابه
Effect of Light Intensity on the Degree of Conversion of Dual-cured Resin Cement at Different Depths with the use of Translucent Fiber Posts
OBJECTIVES To evaluate the effect of different light intensities on the degree of conversion (DC) of dual-cured resin cement at different depths of translucent fiber posts. MATERIALS AND METHODS Thirty translucent fiber posts were randomly assigned into three (n=10) groups. They were cemented in the simulated canal spaces using Duo-Link dual-cured resin cement. The cement was light-cured unde...
متن کاملپلیمریزاسیون سیمانهای رزینی دوال کیور کاربردی جهت چسباندن پستهای فایبری همرنگ دندان
Background and Aim: Insufficient polymerization of resin cements is of considerable clinical importance, because of mechanical deficiencies and biological side effects of uncured resin. Dual cure resin cements are getting popular in luting tooth colored posts and although their curing is claimed to proceed chemically, polymerization efficiency in deep areas of canal is uncertain. The aim of thi...
متن کاملBond strength of fiber posts to weakened roots after resin restoration with different light-curing times.
INTRODUCTION This study evaluated the bond strength of translucent fiber posts to experimentally weakened radicular dentin restored with composite resin and polymerized with different light-exposure time. METHODS Roots of 60 maxillary incisors were used. Twenty-four hours after obturation, the filling materials of root canals were removed to a depth of 12 mm, and 4 groups were randomly formed...
متن کاملDegree of conversion of dual-cured resin cement light-cured through three fibre posts within human root canals: an ex vivo study.
AIM To evaluate the degree of conversion of one dual-cured resin cement light-cured through three fibre posts within extracted human teeth. METHODOLOGY Fifteen mandibular premolars were root filled and then divided into three groups. Variolink II was light-cured through the posts (LP, D.T. Light-Post; PP, FRC Postec Plus; SP, Snowpost) within the root canal. The degree of conversion was obtai...
متن کاملIn Vitro Effect of Zirconia and Zirconia Enriched Glass Fiber Composite Posts on Fracture Resistance of Endodontically Treated Teeth
Objective: Despite the advantages of esthetic posts, lack of studies on their fracture resistance has limited their clinical use. This study aimed to compare the effect of two types of esthetic posts namely zirconia and zirconia enriched glass fiber composite posts on fracture resistance of endodontically treated teeth against compressive forces. Methods: This in vitro study was conducted o...
متن کامل