An automated p-nitrophenylphosphate serum alkaline phosphatase procedure for the "Robot Chemist".

نویسندگان

  • S Morgenstern
  • G Kessler
  • J Auerbach
  • R V Flor
  • B Klein
چکیده

A new, precise, and accurate procedure is described for the automated determination of serum alkaline phosphatase on the Robot Chemist. The substrate, p-nitrophenylphosphate in 2-amino-2-methyl-1-propanol, offers the prime advantage of providing directly its own chromogen, p-nitrophenol, following enzyme action. Other advantages are the small sample volumes required and linear reaction rates. Correlations are presented between the manual procedure and those used with both the Technicon AutoAnalyzer and the Robot Chemist.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An automated p-nitrophenylphosphate serum alkaline phosphatase procedure for the AutoAnalyzer.

A new and simplified procedure for the automated determination of serum alkaline phosphatase uses the AutoAnalyzer. The substrate p-nitrophenylphosphate in 2amino-2-methyl-l-propanol offers the prime advantage of providing directly its own chromogen, p-nitrophenol, following enzyme action. The procedure also permits use of small sample volumes, provides linear reaction rates, and has a simple m...

متن کامل

Automated determination of acid phosphatase. II. Technic for using robot chemist.

A procedure is presented for the automated determination of acid phosphatase activity in biological materials using the Robot Chemist. Although either phenylphosphate and a-naphthylphosphate may be used as substrate in this analysis, the procedure is described in detail for serum acid phosphatase using a-naphthylphosphate in 0.1 M citrate, pH 5.2, since this substrate is more selective for pros...

متن کامل

Effect of incubation with Mg2+ on the measurement of alkaline phosphatase activity.

Human serum incubated with 2-amino-2-methyl-1-propanol (860 mmol/liter) and magnesium ion (270 mumol/liter) at pH 10.35 showed greater alkaline phosphatase (EC 3.1.3.1) activity than if an equal amount of magnesium ion was added at the time of measurement. The apparent increase is due in part to a slight lability of serum alkaline phosphatase in 2-amino-2-methyl-1-propanol, which is prevented b...

متن کامل

Alkaline phosphatase activity of polymorphonuclear leucocytes and lymphocytes separated from normal human blood.

Suspensions of polymorphonuclear leucocytes and lymphocytes were prepared from normal human blood by the glass bead column method of Rabinowitz (1964). The alkaline phosphatase activity of the separated cells was determined by biochemical and cytochemical techniques. Lymphocytes were found to contain an enzyme catalysing the hydrolysis of beta-glycerophosphate at alkaline pH but not of p-nitrop...

متن کامل

An automated alkaline phosphatase assay with phenolphthalein monophosphate as substrate.

The manual procedure of Babson et al. (1) for the determination of serum alkaline phosphatase has been automated. The assay is based on the colorimetric determination of phenolphthalein formed on hydrolysis of phenolphthalein monophosphate. The procedure utilizes 0.16 ml. of serum without dialysis. Blanks are required only for turbid sera. Results are compared with those obtained by the manual ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 11 9  شماره 

صفحات  -

تاریخ انتشار 1965