Radiation damage in room-temperature data acquisition with the PILATUS 6M pixel detector

نویسندگان

  • Chitra Rajendran
  • Florian S. N. Dworkowski
  • Meitian Wang
  • Clemens Schulze-Briese
چکیده

The first study of room-temperature macromolecular crystallography data acquisition with a silicon pixel detector is presented, where the data are collected in continuous sample rotation mode, with millisecond read-out time and no read-out noise. Several successive datasets were collected sequentially from single test crystals of thaumatin and insulin. The dose rate ranged between ∼ 1320 Gy s(-1) and ∼ 8420 Gy s(-1) with corresponding frame rates between 1.565 Hz and 12.5 Hz. The data were analysed for global radiation damage. A previously unreported negative dose-rate effect is observed in the indicators of global radiation damage, which showed an approximately 75% decrease in D(1/2) at sixfold higher dose rate. The integrated intensity decreases in an exponential manner. Sample heating that could give rise to the enhanced radiation sensitivity at higher dose rate is investigated by collecting data between crystal temperatures of 298 K and 353 K. UV-Vis spectroscopy is used to demonstrate that disulfide radicals and trapped electrons do not accumulate at high dose rates in continuous data collection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Message from the Director Steven Ealick

In May 2009, NE-CAT applied for a high end equipment grant from NCRR to fund the purchase of a Pixel Array Detector (PAD). As a class, PADs are generally acknowledged as the near-term successor to CCD’s at 3rd generation synchrotron crystallography beamlines. The PILATUS-6M, from Dectris Ltd., is the first commercially available PAD suitable for synchrotron-based macromolecular crystallographic...

متن کامل

Performance of single-photon-counting PILATUS detector modules

PILATUS is a silicon hybrid pixel detector system, operating in single-photon-counting mode, that has been developed at the Paul Scherrer Institut for the needs of macromolecular crystallography at the Swiss Light Source (SLS). A calibrated PILATUS module has been characterized with monochromatic synchrotron radiation. The influence of charge sharing on the count rate and the overall energy res...

متن کامل

Characterization of an in-vacuum PILATUS 1M detector.

A dedicated in-vacuum X-ray detector based on the hybrid pixel PILATUS 1M detector has been installed at the four-crystal monochromator beamline of the PTB at the electron storage ring BESSY II in Berlin, Germany. Owing to its windowless operation, the detector can be used in the entire photon energy range of the beamline from 10 keV down to 1.75 keV for small-angle X-ray scattering (SAXS) expe...

متن کامل

Improved data acquisition in grazing-incidence X-ray scattering experiments using a pixel detector.

The use of an area detector in grazing-incidence X-ray experiments lends many advantages in terms of both speed and reliability. Here a discussion is given of the procedures established using the PILATUS pixel detector developed at the Swiss Light Source for optimizing data acquisition and analysis of surface diffraction data at the Materials Science beamline, especially with regard to reflecti...

متن کامل

Next Generation X-ray Detectors for In-house Xrd

A novel type X-ray detector, called PILATUS, has been developed at the Paul Scherrer Institut (PSI) in Switzerland during the last decade. PILATUS detectors are two-dimensional hybrid pixel array detectors, which operate in single-photon counting mode. PILATUS detectors feature a very wide dynamic range (1:1,000,000), very short read out time (< 3.0 msec), no readout noise, and very high counti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2011