Concordance Between Iothalamate and Iohexol Plasma Clearance.

نویسندگان

  • Pierre Delanaye
  • François Jouret
  • Caroline Le Goff
  • Etienne Cavalier
چکیده

To the Editor: Iohexol is regarded as an accurate filtration marker for measuring GFR. Recently, Soveri et al concluded that plasma clearance of iohexol could be considered a valid alternative to the gold standard, urinary clearance of inulin. Because inulin urinary clearance is cumbersome and costly, iohexol and iothalamate clearance have become popular in Europe and the United States, respectively. To advance GFR research, it therefore seems relevant to directly compare these 2 methods. Seegmiller et al recently highlighted discordance between urinary clearance of iothalamate and iohexol measured by LC-MS/MS; iohexol clearance wasw15% lower than iothalamate clearance. However, at least for iohexol, plasma disappearance is generally used in clinical practice and research. Here, we concomitantly measured GFR by plasma clearance of both iohexol and iothalamate in 102 patients. Indications for GFR measurement were kidney function evaluation in either potential living kidney donors or patients whose serum creatinine–based GFR estimation was suspected as inaccurate. The protocol had ethics committee approval (Belgian number: B7072014220701). All patients signed informed consent. Five mL of iohexol (Omnipaque 240, 240 mg/mL; GE Healthcare BVBA) and 5 mL of iothalamate (Conray 30; iothalamate meglumine, 141 mg/mL; Covidien) were administered simultaneously in the same vein (antecubital, forearm, or hand vein) and flushed with 10 mL of normal saline solution. Blood samples were obtained using the contralateral arm at 120, 180, 240, and 300 minutes after injection and GFR was calculated as per Brochner-Mortensen. Samples were centrifuged for 10 min at 3,000 g within 2 hours of collection and stored at280 C. Iohexol was measured by 2 methods (HPLC, as previously described, and LC-MS/MS); iothalamate was measured by LC-MS/MS (analytical methods in Item S1). Our laboratory participates in interlaboratory quality control performed by Equalis AB (Uppsala, Sweden) using both methods 4 times a year. Clearance results were analyzed by Passing-Bablok regressions and concordance correlation coefficient (CCC). For Bland-Altman analysis, we calculated relative bias as the mean

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of the Chronic Kidney Disease Epidemiology Collaboration equation to estimate glomerular filtration rate in a longitudinal study of Autosomal Dominant Polycystic Kidney Disease

Glomerular filtration rate (GFR) can only be measured indirectly1. The gold standard is the renal clearance of inulin. Because it is cumbersome, alternative methods such as the renal clearance of iothalamate and plasma clearance of iohexol were developed. Other methods estimate GFR using equations based on endogenous filtration markers such as creatinine and cystatin C2. The Chronic Kidney Dise...

متن کامل

Measured GFR as a confirmatory test for estimated GFR.

Clinical assessment of kidney function is central to the practice of medicine. GFR is widely accepted as the best index of kidney function in health and disease, and accurate values are required for optimal decision making. Estimated GFR based on serum creatinine is now widely reported by clinical laboratories, and in most circumstances, estimated GFR is sufficient for clinical decision making....

متن کامل

Evaluation of a new immunoassay for cystatin C, based on a double monoclonal principle, in men with normal and impaired renal function

BACKGROUND Elevated cystatin C in blood reflects impaired glomerular filtration rate (GFR), but current cystatin C assays, based on polyclonal antibodies and immunoturbidimetric or nephelometric detection, have several limitations. We evaluated a new immunoassay based on monoclonal antibodies in samples from patients with and without chronic kidney disease (CKD). METHODS The study enrolled 17...

متن کامل

Neuroangiography with lohexol

lohexol is a new, non ionic water-soluble contrast agent undergoing early clinical trials in the United States. Using a doubleblind , parallel format, iohexol was compared with meglumine iothalamate (60 patients) for selective cerebral angiography, and with sodium meglumine diatrizoate (40 patients) for arch aortography. lohexol produced significantly less pain than meglumine iothalamate or sod...

متن کامل

Radiocontrast agents induce endothelin release in vivo and in vitro.

The intravascular administration of the ionic radiocontrast agent sodium iothalamate (2.9 g of iodine/kg body wt) to rats induced an increase in plasma concentration of immunoreactive endothelin from 21.3 +/- 1.2 to 36 +/- 3 fmol/mL, preceded by a transient rise in the plasma level of atrial natriuretic peptide and associated with a fall in RBF. Equi-iodine amounts of the nonionic agents ioxagl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of kidney diseases : the official journal of the National Kidney Foundation

دوره 68 2  شماره 

صفحات  -

تاریخ انتشار 2016