All-diamond optical assemblies for a beam-multiplexing X-ray monochromator at the Linac Coherent Light Source

نویسندگان

  • S. Stoupin
  • S. A. Terentyev
  • V. D. Blank
  • Yu. V. Shvyd’ko
  • K. Goetze
  • L. Assoufid
  • S. N. Polyakov
  • M. S. Kuznetsov
  • N. V. Kornilov
  • J. Katsoudas
  • R. Alonso-Mori
  • M. Chollet
  • Y. Feng
  • J. M. Glownia
  • H. Lemke
  • A. Robert
  • M. Sikorski
  • S. Song
  • D. Zhu
چکیده

A double-crystal diamond (111) monochromator recently implemented at the Linac Coherent Light Source (LCLS) enables splitting of the primary X-ray beam into a pink (transmitted) and a monochromatic (reflected) branch. The first monochromator crystal, with a thickness of ∼100 µm, provides sufficient X-ray transmittance to enable simultaneous operation of two beamlines. This article reports the design, fabrication and X-ray characterization of the first and second (300 µm-thick) crystals utilized in the monochromator and the optical assemblies holding these crystals. Each crystal plate has a region of about 5 × 2 mm with low defect concentration, sufficient for use in X-ray optics at the LCLS. The optical assemblies holding the crystals were designed to provide mounting on a rigid substrate and to minimize mounting-induced crystal strain. The induced strain was evaluated using double-crystal X-ray topography and was found to be small over the 5 × 2 mm working regions of the crystals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of a beam-multiplexing diamond crystal monochromator at the Linac Coherent Light Source.

A double-crystal diamond monochromator was recently implemented at the Linac Coherent Light Source. It enables splitting pulses generated by the free electron laser in the hard x-ray regime and thus allows the simultaneous operations of two instruments. Both monochromator crystals are High-Pressure High-Temperature grown type-IIa diamond crystal plates with the (111) orientation. The first crys...

متن کامل

Demonstration of simultaneous experiments using thin crystal multiplexing at the Linac Coherent Light Source

Multiplexing of the Linac Coherent Light Source beam was demonstrated for hard X-rays by spectral division using a near-perfect diamond thin-crystal monochromator operating in the Bragg geometry. The wavefront and coherence properties of both the reflected and transmitted beams were well preserved, thus allowing simultaneous measurements at two separate instruments. In this report, the structur...

متن کامل

Linac Coherent Light Source soft x-ray materials science instrument optical design and monochromator commissioning.

We present the x-ray optical design of the soft x-ray materials science instrument at the Linac Coherent Light Source, consisting of a varied line-spaced grating monochromator and Kirkpatrick-Baez refocusing optics. Results from the commissioning of the monochromator are shown. A resolving power of 3000 was achieved, which is within a factor of two of the design goal.

متن کامل

An accumulative x-ray streak camera with sub-600-fs temporal resolution and 50-fs timing jitter

Related Articles Compact x-ray microradiograph for in situ imaging of solidification processes: Bringing in situ x-ray micro-imaging from the synchrotron to the laboratory Rev. Sci. Instrum. 82, 105108 (2011) Simultaneous sample and spatial coherence characterisation using diffractive imaging Appl. Phys. Lett. 99, 154103 (2011) Heat transfer simulation and thermal measurements of microfabricate...

متن کامل

Chirped-beam two-stage free-electron laser for high-power femtosecond x-ray pulse generation

A method for generating femtosecond-duration x-ray pulses with a free-electron laser is presented. This method uses an energy-chirped electron beam propagating through an undulator to produce a frequencychirped x-ray pulse by self-amplified spontaneous emission. A short temporal pulse is created by use of a monochromator to select a narrow radiation bandwidth. A second undulator is used to ampl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 47  شماره 

صفحات  -

تاریخ انتشار 2014