Problems in the disinfection of class 1 microbiology safety cabinets.
نویسندگان
چکیده
Microbiology safety cabinet disinfection procedures using formaldehyde have been tested. Tubercle bacilli were killed by concentrations of formaldehyde obtained by heating commercial formalin irrespective of whether the bacilli were in the cabinet free space or above the prefilters. However, Bacillus stearothermophilus spore papers for for the testing of low temperature steam/formaldehyde sterilisers were almost never sterilised and a strain of Staphylococcus epidermidis (NCTC 7944) showed a resistance intermediate between the B stearothermophilus spores and the tubercle bacilli. Tests using a vaccine strain of poliovirus type 3 indicated a considerable degree of resistance of the virus to the action of formaldehyde. No such resistance was demonstrated by vaccinia virus or echovirus 14. Chemical and biological evidence is presented which indicates that filter paper discs are an unsuitable carrier material for a challenge organism in testing the efficiency of any formaldehyde sterilising process. Recommendations are made towards developing a satisfactory test procedure.
منابع مشابه
Performance of exhaust-protective (class I) biological 'safety' cabinets.
Nineteen open-fronted (class I) safety cabinets were subjected to spore containment and airflow tests, which suggested that a flow of 0.75 m/s was the minimum required for safe operation; further tests on three of the cabinets were repeated at different air speeds and confirmed this. The airflow is required to overcome the effect of laboratory or external air currents. Contamination of surfaces...
متن کاملMeasuring the Loss of Dexterity during Microbiological Containment Systems Use
Microbiology laboratories use containment equipment such as safety cabinets and isolators or respiratory protective equipment to protect workers against aerosol infection hazards. There is a perception amongst microbiologists that using sharps within containment equipment would increase the operator’s chance of accidental injury due to losses of dexterity within containment and so respiratory p...
متن کاملMeasuring the Loss of Dexterity during Microbiological
Microbiology laboratories use containment equipment such as safety cabinets and isolators or respiratory protective equipment to protect workers against aerosol infection hazards. There is a perception amongst microbiologists that using sharps within containment equipment would increase the operator’s chance of accidental injury due to losses of dexterity within containment and so respiratory p...
متن کاملUse of an organoleptic tracer (mercaptan) for testing for leaks in safety equipment.
A safe, rapid, sensitive, and economical method is presented for detecting leaks in gas-tight laboratory cabinets and other apparatus. This method, using no fluorocarbons and requiring no prior decontamination, is effective under negative, neutral, or positive chamber conditions.
متن کاملBacterial communities in PM2.5 and PM10 inside the cage broiler houses before and after disinfection
Background: Air in broiler houses is contaminated with considerable amounts of microbial aerosols, which affects the health of humans and birds. Thorough cleaning and disinfecting should be carried out to reduce particulate concentrations and minimize airborne microorganisms. Aims: To evaluate the effects of cleaning and disinfecting measures on bacterial commu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical pathology
دوره 35 7 شماره
صفحات -
تاریخ انتشار 1982