Effect of instructions on conventional automated perimetry.
نویسندگان
چکیده
PURPOSE To investigate the effect of perimetrists' instructions on automated perimetry thresholds. METHODS Eighteen volunteers in two age groups participated in a series of three test sessions. Each session consisted of a Humphrey Field Analyzer 30-2 test, a questionnaire, and a customized test program using a Humphrey perimeter to construct frequency of seeing (FOS) curves from which thresholds were calculated, and a descriptive measure of response criterion was derived. The FOS curves were obtained at a central and a peripheral test location within the same test session. The three test sessions differed only by the instructions given. The instructions were adapted from those listed in the manufacturer's instruction manual and were designed to influence participants to respond to the stimuli in a conservative, liberal, or neutral manner. RESULTS For the 30-2 threshold test, a significant difference in mean deviation was found among the three instruction types (P = 0.001) and between the two age groups (P = 0.001). Although differences were small in the younger subjects (2.04 dB), the means for the responses from liberal to conservative differed by 6.57 dB in the older subjects. Thresholds obtained in a peripheral location by the customized threshold test were found to differ significantly between the age groups (younger group mean, 31.0 dB; older group mean, 27.2 dB) and among the instruction types (liberal mean, 30.9 dB; conservative mean, 28.1 dB; and neutral mean, 30.3 dB; P < 0.001). The descriptive measurement of response criterion suggests that a difference in criteria occurred as a result of the instructions in both peripheral and central locations for both age groups (P = 0.0001). In addition, according to self-reports, liberal instructions caused participants to be more likely to respond, whereas the conservative instructions caused them to be more reluctant to respond. CONCLUSIONS Perimetrists' instructions can significantly affect obtained automated perimetry thresholds.
منابع مشابه
The effect of attention on conventional automated perimetry and luminance size threshold perimetry.
PURPOSE To investigate the effects of divided attention on conventional automated perimetry (CAP) and luminance size threshold perimetry (LSTP). METHODS Ten healthy subjects, ages 27 to 65, with two perimetry types (CAP and LSTP) were tested in random order. At a later session, these tests were given with a mental workload to simulate the effect of anxiety or distraction on subjects performin...
متن کاملHigh spatial resolution automated perimetry in glaucoma.
BACKGROUND Automated perimetry is of fundamental importance in assessing visual function in glaucoma. A technique was evaluated to perform high spatial resolution automated perimetry to allow a more detailed assessment of the luminance sensitivity in selected regions of the visual field than is possible with conventional perimetry. METHOD High spatial resolution perimetry was performed using ...
متن کاملEffect of Yellow-Tinted Intraocular Lens on Standard Automated Perimetry and Short Wavelength Automated Perimetry in Patients with Glaucoma
PURPOSE To investigate the effect of cataract surgery and yellow-tinted intraocular lens (IOLs) implantation on perimetry indices of short-wavelength automated perimetry (SWAP) and standard automated perimetry (SAP) testing in patients with coexisting cataract and glaucoma. MATERIALS AND METHODS In this prospective comparative case series, phacoemulsification with implantation of yellow-tinte...
متن کاملA Comparison of the Effects of Neutral Density Filters and Diffusing Filters on Motion Detection Perimetry, White-on-white Perimetry and Frequency Doubling Perimetry
Background: Motion detection perimetry and frequency doubling perimetry are methods that have been developed with the goal of detecting glaucomatous field defects earlier than conventional white-on-white perimetry. It is well recognized that the development of cataract and pupillary constriction can significantly influence perimetric thresholds when screening for, or following the progression o...
متن کاملA comparison of Goldmann and Humphrey automated perimetry in patients with glaucoma.
Humphrey automated threshold perimetry (Program 30-2) was performed on 42 eyes of 25 patients with glaucoma to determine both the sensitivity and specificity of automated perimetry in detecting glaucomatous visual field defects. Automated perimetry sensitivity was 90.38%, while automated perimetry specificity was 91%. Fifty-two patients and a technician took part in a survey to determine their ...