Calibrating Passive Neutron Multiplicity and Waste Counters Using Calibrated Cf Sources: Estimating aPu-Values Without Pu
نویسندگان
چکیده
Cf sources are especially interesting for calibrating passive multiplicity counters without the need for Pu because: they are genuinely point-like and being lightly encapsulated offer a nearly isotropic unperturbed fission spectrum of neutrons for all practical purposes they can be considered as a pure source of spontaneous fission neutrons which considerably simplifies interpolation. That is the leakage self multiplication, ML, can be taken as unity and the ratio α of (α, n)-to-(SF, n) neutrons can be taken as zero. it is a well studied multiplicity system with the factorial moments νi of the distribution P(ν) being well established. the energy spectrum is similar to that of the spontaneous spectra of the Pu isotopes it is readily available with well known outputs , Y, determined absolutely by reference to Mn-baths operated by National Standards Laboratories In this work we exploit these features in the framework of the point-model interpretational equations discussed in ASTM C 1500 ‘Standard Test Method for Nondestructive Assay of Plutonium by Passive Neutron Multiplicity Counting’. In particular we: extend the equations to include the delayed neutron contribution showing how to extract the gate utilization factors (GUFs) accurately from the data available; extend the solutions given in the Appendices to cases where the Triples GUF is not equal to the square of the Doubles GUF; and, illustrate how to project Pueff performance from measured Cf.
منابع مشابه
New Shift-register Electronics for Improved Precision of Neutron Coincidence and Multiplicity Assays of Plutonium and Uranium Mass
Active and passive neutron-coincidence counting (NCC) is used routinely for nondestructive assay (NDA) of uranium and plutonium, in many forms. Passive neutron multiplicity counting (PNMC) is used routinely for NDA of plutonium scrap and waste. We’ve developed and extensively tested new electronics that significantly improves precision of double and triple coincidences, and multiplicity assays....
متن کاملPrecision of the Accidentals Rate in Neutron Coincidence Counting
The quantification of Pu present, for example, as process hold-up in glove boxes or in waste containers may be accomplished by passive neutron coincidence counting (PNCC) to determine the Pu-240 effective mass which may then be related to the total Pu mass or Pu-239 mass through the isotopic composition. When multiplication can reasonably be taken as slight, assay results are normally based on ...
متن کاملCalibration of a Tld Albedo Individual Neutron Monitor
Neutron individual monitoring is considerably less established than photon individual monitoring. The main difficulty is the impossibility to find a detector that covers the large occupational neutron energy range. All commercial individual monitors have strong energy dependence. Another difficulty is to calibrate an individual neutron monitor in the ISO 21909 established energy operational ran...
متن کاملMonte Carlo Hauser - Feshbach predictions of prompt fission γ rays : Application to n th + 235 U , n th + 239 Pu , and 252 Cf ( sf )
The prompt neutron and γ emission from primary fission fragments are calculated for thermal neutron induced fission of 235U and 239Pu and for spontaneous fission of 252Cf using a Monte Carlo Hauser-Feshbach approach for the evaporation of the excited fission fragments. Remaining free model parameters, such as excitation energy sharing and initial spin distribution, are determined by comparison ...
متن کاملشبیهسازی مونت کارلو یک دستگاه پرتودهی نوترونی به منظور تعیین بازده آشکارسازهای نوترونهای حرارتی
In this work, a neutron irradiating system containing six Am/Be neutron sources in a graphite moderator, which produces a relatively high and uniform thermal neutron flux in an irradiating cavity at the center of the system , has been simulated .The thermal neutron flux in the center of the system has then been calculated and compared with experimental results measured in a cavity a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2005