Implementing capsule representation in a total hip dislocation finite element model.

نویسندگان

  • Kristofer J Stewart
  • Douglas R Pedersen
  • John J Callaghan
  • Thomas D Brown
چکیده

Previously validated hardware-only finite element models of THA dislocation h ave clarifiedhow various component design and surgical placement variables contribute to resisting the propensity for implant dislocation. This body of work has now been enhanced with the incorporation of experimentally based capsule representation, and with anatomic bone structures. The current form of this finite element model provides for large deformation multi-body contact (including capsule wrap-around on bone and/or implant), large displacement interfacial sliding, and large deformation (hyperelastic) capsule representation. In addition, the modular nature of this model now allows for rapid incorporation of current or future total hip implant designs, accepts complex multi-axial physiologic motion inputs, and outputs case-specific component/bone/soft-tissue impingement events. This soft-tissue-augmented finite element model is being used to investigate the performance of various implant designs for a range of clinically-representative soft tissue integrities and surgical techniques. Preliminary results show that capsule enhancement makes a substantial difference in stability, compared to an otherwise identical hardware-only model. This model is intended to help put implant design and surgical technique decisions on a firmer scientific basis, in terms of reducing the likelihood of dislocation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The capsule's contribution to total hip construct stability--a finite element analysis.

Instability is a significant concern in total hip arthroplasty (THA), particularly when there is structural compromise of the capsule due to pre-existing pathology or due to necessities of surgical approach. An experimentally grounded fiber-direction-based finite element model of the hip capsule was developed, and was integrated with an established three-dimensional model of impingement/disloca...

متن کامل

Biomechanics of failure modalities in total hip arthroplasty

Total hip arthroplasty (THA) is the treatment of choice to relieve joint pain and loss of mobility as a result of advanced stage osteoarthritis or other hip pathologies. Despite their general success, THAs do fail, with revision rates estimated near 5% per year. Instability, defined as the complete subluxation (dislocation) of the femoral head from the acetabular socket – which usually occurs d...

متن کامل

Ceramic Total Hip Liner Fracture Modeling in Abaqus using co-Simulation and Extended Finite Element Modeling

Due to concerns over particle generation in conventional metal-on-polyethylene hip bearings used in total hip arthroplasty (THA), interest in advanced low-wear bearing alternatives such as ceramic-on-ceramic (CoC) couples has reemerged. While ceramics demonstrate excellent compressive strength, the brittle nature of the material reduces tensile strength, possibly leading to catastrophic fractur...

متن کامل

Development of Human Hip Capsule Finite Element Model

The current study focuses on the development of a finite element model of the hip capsule ligament to represent the joint between the femur and the pelvis. The finite element model of the hip capsule is represented as comprising of eight sectors, consisting of the important ligaments in those regions of the capsule. The geometric parameters for the capsule are determined from available literatu...

متن کامل

Range of Movement for Impingement and Dislocation Avoidance in Total Hip Replacement Predicted by Finite Element Model

Dislocation is a serious complication in total hip replacement (THR). An inadequate range of movement (ROM) can lead to impingement of the prosthesis neck on the acetabular cup; furthermore, the initiation of subluxation and dislocation may occur. The objective of this study was to generate a parametric three-dimensional finite element (FE) model capable of predicting the dislocation stability ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Iowa orthopaedic journal

دوره 24  شماره 

صفحات  -

تاریخ انتشار 2004