Intraocular pressure and central corneal thickness.
نویسندگان
چکیده
From the results of the Ocular Hypertension Treatment Study emerged the conclusion that ocular hypertensive subjects with thinner central corneal thickness (CCT) are at increased risk of developing glaucoma. Although possible underlying biases that could have led to this conclusion are still under investigation, there is an increasing interest in the scientific community to understand the potential mechanisms of this increased risk profile. It has been proposed that interindividual differences in CCT might be purely responsible for inaccuracies of the tonometric readings with potential underestimation of the true IOP in subjects with thinner CCT although it is becoming progressively clearer that the true IOP is unpredictable with linear correction formulas for CCT, and it is likely that other material properties of the cornea contribute, together with CCT, to the tonometric artifact. Recently, it has become possible to measure the biomechanical properties of the cornea in vivo and it has been suggested that differences in corneal biomechanics may be the expression of interindividual structural differences of the ocular tissues (including lamina cribrosa), with potential consequences on the interindividual susceptibility to the glaucomatous damage under the same IOP level. A possible underlying biological risk related to thinner CCTs, independent of the influence on tonometric reading, has been proposed and largely studied after the results of the OHTS were published. Besides the understanding of the mechanism underlying the role of CCT as a risk factor for the development of glaucoma, it is important to understand how the information about CCT should be integrated in the clinical management of both ocular hypertension (OHT) and glaucoma and whether other ocular properties should be measured to better understand the individual risk profile.
منابع مشابه
بررسی ارتباط بین ضخامت مرکز قرنیه و میزان فشار داخل چشمی اندازه گیری شده با تونومتر گلدمن
To determine the effect of central corneal thickness (CCT) on measured intraocular pressure (IOP) and evaluating the relationship between them in each of the groups of patients including: Normal subjects, ocular hypertension patients and patients with primary open angle glucoma (POAG). Correlation between intraocular pressure (Measured by Goldman applanation tonometer) and central corneal thick...
متن کاملCorrelation between central corneal thickness and intraocular pressure peak and fluctuation during the water drinking test in glaucoma patients
OBJECTIVE To investigate the correlation between central corneal thickness and outflow facility assessed by intraocular pressure peak and fluctuation during the water drinking test. METHODS Fifty-five newly diagnosed primary open-angle glaucoma patients submitted to central corneal thickness measurements and water drinking test were enrolled in this retrospective study.;. Patients were divide...
متن کاملEffect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer.
AIMS To investigate the effect of central corneal thickness and corneal curvature on intraocular pressure measurements using the pulsatile ocular blood flow tonograph and the Goldmann applanation tonometer, and to assess the agreement between the pulsatile ocular blood flow tonograph and the Goldmann applanation tonometer in intraocular pressure measurement. METHODS 479 subjects underwent int...
متن کاملIntraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea
Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...
متن کاملThe Heritability of Glaucoma-Related Traits Corneal Hysteresis, Central Corneal Thickness, Intraocular Pressure, and Choroidal Blood Flow Pulsatility
PURPOSE The purpose of this work was to investigate the heritability of potential glaucoma endophenotypes. We estimated for the first time the heritability of the pulsatility of choroidal blood flow. We also sought to confirm the heritability of corneal hysteresis, central corneal thickness, and 3 ways of measuring intraocular pressure. METHODS Measurements were performed on 96 first-degree r...
متن کاملCorrelation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.
PURPOSE The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, cent...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Progress in brain research
دوره 173 شماره
صفحات -
تاریخ انتشار 2008