Single Stage Treatment of Non – Union of Transcervical Neck Femur Fracture with Shepherd Crook Deformity of Proximal Femur in A Case of Fibrous Dysplasia using Dynamic Hip Screw Fixation
نویسندگان
چکیده
INTRODUCTION Fibrous dysplasia is a rare benign disorder of the skeletal system characterized by fibro osseous proliferation with intervening areas of normal or immature bone in the intramedullary region. It can either be a monostotic (involves one bone) or a polyostotic (involves more than one bone) presentation and usually occurs equally in males and females. Deformities like scoliosis and shepherd's crook deformity are frequently encountered in the polyostotic form. We report a rare managed case of bilateral non-union of the pathological fracture of femur neck with shepherd's crook deformity of the proximal femur in a case of polyostotic fibrous dysplasia. CASE REPORT A 16 years old female case of polyostotic fibrous dysplasia had bilateral Shepherd's crook deformity of the proximal femur with bilateral non - union of pathological fracture of neck femur. We managed each side in one stage with two osteotomies. On the right side, first oblique osteotomy was done from just distal to the greater trochanter up to the level of the neck and the second; lateral closing wedge abduction osteotomy was done at the subtrochanteric level. 2 months later on the left side double lateral closing wedge abduction osteotomies were performed both at the subtrochanteric level. Fixation of both the sides was done using a 135° Dynamic Richard's screw with a long side plate to span the osteotomy sites and the lesion. Post - operatively we achieved a neck shaft angle of 135° on right side and 133° on the left side. Follow up imaging showed union at both the osteotomy sites bilaterally and also at the site of the pathological fracture of neck femur. Presently, at 18 months post - operatively, patient is walking full weight bearing without support and there are no signs of recurrence of lesions of fibrous dysplasia or the deformity. CONCLUSION Double osteotomy is an easy and effective method to correct the shepherd's crook deformity and achieve correct mechanical alignment. Dynamic hip screw with long side plate is a versatile implant to tackle the proximal femur deformity. Double osteotomy corrects the deformity and tackles the associated problems like non - union of the pathological neck femur fracture in one stage.
منابع مشابه
Fibrous dysplasia of the proximal femur: surgical management options and outcomes
PURPOSE The management of proximal femoral deformity in fibrous dysplasia (FD) is a challenge to the orthopaedic surgeon. The purpose of this study was to analyze the various presentations of FD of proximal femur and the results of the various treatment modalities for the same. METHODS This is a retrospective cohort study of 23 patients (24 femora) with FD who underwent surgery for the proxim...
متن کاملFibrous Dysplasia of Proximal Femur: Management of the Complications
Fibrous dysplasia represents about 5% of benign bone lesions; however, the true incidence is unknown, as many patients are asymptomatic. Monostotic fibrous dysplasia accounts for 75-80% of the cases. It is caused by gene mutation [1,2]. Fibrous dysplasia is a slowly growing lesion that usually appears during periods of bone growth and is thus seen in those in early teen and adolescent years. Po...
متن کاملOne-stage osteotomy and fixation using a long proximal femoral nail and fibular graft to correct a severe shepherd's crook deformity in a patient with fibrous dysplasia: a case report.
We report a case where a one-stage osteotomy and fixation, using a long proximal femoral nail and fibular graft, was performed to correct a severe shepherd's crook deformity (70-degree varus and 50-degree retroversion) of the femoral neck with a pathological stress fracture in a patient with fibrous dysplasia. The neck shaft angle was corrected to 125 degrees. At the 57-month follow-up, the pat...
متن کاملA Modified Technique of Fixation for Proximal Femoral Valgus Osteotomy in Abnormal Bone: A Report of Two Cases
The ideal size of intramedullary device to fix corrective osteotomy of proximal femur in abnormal bone in children and small patients may not be easily available. We report the successful use of Rush rod in combination with multiple Kirschner wires to fix the corrective osteotomy of coxa vara and shepherd crook deformity in two patients with osteogenesis imperfecta and fibrous dysplasia. The un...
متن کاملSurgical treatment of fibrous dysplasia in the proximal femur
The aim of this study was to summarize oncological and functional results and to investigate surgical treatment methods and efficacies by conducting a retrospective study of patients with fibrous dysplasia (FD) in the proximal femur. A total of 15 patients with FD in the proximal femur were selected. Among them, 12 cases were monostotic and 3 cases were polyostotic. In addition, 2 cases were ac...
متن کامل