Flow injection fluorometric determination of ascorbic acid using perylenebisimide-linked nitroxide.

نویسندگان

  • Tomoharu Maki
  • Nobuaki Soh
  • Koji Nakano
  • Toshihiko Imato
چکیده

A simple and sensitive flow injection fluorometric method for the determination of ascorbic acid is described. Perylenebisimide-linked nitroxide (PBILN) is used as a fluorescent reagent, which permits the selective determination of ascorbic acid. The fluorescence of the perylenebisimide moiety in PBILN is quenched by the nitroxide moiety, which is linked to the perylenebisimide. When a stream of a solution of ascorbic acid is merged with a stream of PBILN, the ascorbic acid reacts with the nitroxide moiety of PBILN to form hydroxylamine, and the fluorescence properties of the perylenebisimide moiety are recovered. As a result, a peak-shaped fluorescence signal is produced, which can be observed by a fluorescence detector located downstream. Under optimized conditions, a good linear relationship between the concentration of ascorbic acid and peak height in the concentration range from 0.5 to 10 μmol L(-1) was found and the detection limit (S/N=3) was 0.28 μmol L(-1). The relative standard deviation for the determination of 4.0 μmol L(-1) ascorbic acid samples was 1.0% (n=5). The proposed method was applied to the determination of ascorbic acid in several soft drink beverages and the analytical results were in good agreement with those obtained using a conventional method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flow-Injection Amperometric Determination of Ascorbic Acid Using a Graphite-Epoxy Composite Electrode Modified with Cobalt Phthalocyanine

A flow injection method is reported for the determination of ascorbic acid based on amperometric detection, using a cobalt(II) phthalocyanine (CoPc) modified graphite-epoxy electrode. The amperometric respons was evaluated with regard to pH, ionic strength of the electrolyte, flow rate of the carrier solution, injected sample volume and conditioning time of the electrode. The limit of detec...

متن کامل

Selective Determination of Dopamine in the Presence of Ascorbic Acid and Uric Acid at Neutral pH Using a Silver Nanoparticles-modified Carbon Paste Electrode

Developing simple, sensitive and selective sensing systems for dopamine is important due to its biological significance. In this work, a silver nanoparticles-modified carbon paste electrode (AgNPs-CPE) has been constructed and used to detect of dopamine (DA) in the simultaneous presence of ascorbic acid (AA) and uric acid (UA) at neutral pH 7.0 by cyclic voltammetry. The modified electrode show...

متن کامل

Photometric Determination of Boron with Azomethine-H Using Simplified Two-channel Flow Injection Analysis

A flow injection analysis (FIA) for boron determination was studied using a compact and simple two-channel manifold. This method is based on the chromogenic reaction of borate with azomethine-H to form a yellow complex. The absorbance of the complex was measured at 405 nm. The chemical factors and FIA variables influencing the color development were examined. When a 0.5% (w/v) azomethine-H solu...

متن کامل

Flow-injection determination of ascorbic acid and cysteine simultaneously with spectrofluorometric detection.

A simple and sensitive spectrofluorometric method was developed for the simultaneous determination of ascorbic acid and cysteine by a flow-injection system. This method is based on the reduction of Tl(III) with ascorbic acid or cysteine in acidic media, producing fluorescence reagent, TlCl3(2-) (lambdaex = 227 nm, lambdaem = 419 nm). The injected sample solution was divided into two separate st...

متن کامل

Platinum Nanoparticle Electrode Modified Iodine using Cyclic Voltammetry and Chronoamperometry for Determination of Ascorbic Acid

This study investigated the oxidation of ascorbic acid (Vitamin C) using a platinum nanoparticle electrode coated with an iodine monolayer, called a modified electrode. The electrode were grown using the cyclic voltammetry technique and the electrochemical measurements were taken using the cyclic voltammetry and chronoamperometric technique. In the case of platinum nanoparticle electrode modifi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 85 4  شماره 

صفحات  -

تاریخ انتشار 2011