Respiratory variations in pulse oximetry plethysmographic waveform amplitude to predict fluid responsiveness in the operating room.

نویسندگان

  • Maxime Cannesson
  • Yassin Attof
  • Pascal Rosamel
  • Olivier Desebbe
  • Pierre Joseph
  • Olivier Metton
  • Olivier Bastien
  • Jean-Jacques Lehot
چکیده

BACKGROUND Respiratory variations in pulse oximetry plethysmographic waveform amplitude (DeltaPOP) are related to respiratory variations in pulse pressure (DeltaPP) and are sensitive to changes in preload. The authors hypothesized that DeltaPOP can predict fluid responsiveness in mechanically ventilated patients during general anesthesia. METHODS Twenty-five patients referred for cardiac surgery were studied after induction of general anesthesia. Hemodynamic data (cardiac index, central venous pressure, pulmonary capillary wedge pressure, DeltaPP, and DeltaPOP) were recorded before and after volume expansion (500 ml hetastarch, 6%). Fluid responsiveness was defined as an increase in cardiac index of 15% or greater. RESULTS Volume expansion induced changes in cardiac index (2.0+/-0.4 to 2.3+/-0.5 mmHg; P<0.05), DeltaPP (11+/-7 to 6+/-5%; P<0.05), and DeltaPOP (12+/-9 to 7+/-5%; P<0.05). DeltaPOP and DeltaPP were higher in responders than in nonresponders (17+/-8 vs. 6+/-4 and 14+/-7 vs. 6+/-4%, respectively; P<0.05 for both). A DeltaPOP greater than 13% before volume expansion allowed discrimination between responders and nonresponders with 80% sensitivity and 90% specificity. There was a significant relation between DeltaPOP before volume expansion and percent change in cardiac index after volume expansion (r=0.62; P<0.05). CONCLUSIONS DeltaPOP can predict fluid responsiveness noninvasively in mechanically ventilated patients during general anesthesia. This index has potential clinical applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre.

BACKGROUND Respiratory variations in pulse oximetry plethysmographic waveform amplitude (DeltaPOP) can predict fluid responsiveness in mechanically ventilated patients but cannot be easily assessed at the bedside. Pleth variability index (PVI) is a new algorithm allowing for automated and continuous monitoring of DeltaPOP. We hypothesized that PVI can predict fluid responsiveness in mechanicall...

متن کامل

Comparison between respiratory pulse oximetry plethysmographic waveform amplitude and arterial pulse pressure variations among patients with and without norepinephrine use.

OBJECTIVES Arterial pulse pressure respiratory variation is a good predictor of fluid response in ventilated patients. Recently, it was shown that respiratory variation in arterial pulse pressure correlates with variation in pulse oximetry plethysmographic waveform amplitude. We wanted to evaluate the correlation between respiratory variation in arterial pulse pressure and respiratory variation...

متن کامل

Relation between respiratory variations in pulse oximetry plethysmographic waveform amplitude and arterial pulse pressure in ventilated patients

INTRODUCTION Respiratory variation in arterial pulse pressure is a reliable predictor of fluid responsiveness in mechanically ventilated patients with circulatory failure. The main limitation of this method is that it requires an invasive arterial catheter. Both arterial and pulse oximetry plethysmographic waveforms depend on stroke volume. We conducted a prospective study to evaluate the relat...

متن کامل

Pulse oximeter as a sensor of fluid responsiveness: do we have our finger on the best solution?

The pulse oximetry plethysmographic signal resembles the peripheral arterial pressure waveform, and the degree of respiratory variation in the pulse oximetry wave is close to the degree of respiratory arterial pulse pressure variation. Thus, it is tempting to speculate that pulse oximetry can be used to assess preload responsiveness in mechanically ventilated patients. In this commentary we bri...

متن کامل

Respiratory Variation in Pulse Oximetry: A Simple Fluid Responsiveness Parameter

Respiratory variation in arterial pulse pressure (ΔPP) has been shown to be the most accurate predictor of fluid responsiveness in mechanically ventilated patients, with a predictive cutoff value of 13%. However, this dynamic parameter is invasive and not widely available. The pulse oximetry plethysmographic (POP) signal resembles the arterial pressure waveform in both shape and amplitude varia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 106 6  شماره 

صفحات  -

تاریخ انتشار 2007