Optimal parameters for clinical implementation of breast cancer patient setup using Varian DTS software
نویسندگان
چکیده
Digital tomosynthesis (DTS) was evaluated as an alternative to cone-beam computed tomography (CBCT) for patient setup. DTS is preferable when there are constraints with setup time, gantry-couch clearance, and imaging dose using CBCT. This study characterizes DTS data acquisition and registration parameters for the setup of breast cancer patients using nonclinical Varian DTS software. DTS images were reconstructed from CBCT projections acquired on phantoms and patients with surgical clips in the target volume. A shift-and-add algorithm was used for DTS volume reconstructions, while automated cross-correlation matches were performed within Varian DTS software. Triangulation on two short DTS arcs separated by various angular spread was done to improve 3D registration accuracy. Software performance was evaluated on two phantoms and ten breast cancer patients using the registration result as an accuracy measure; investigated parameters included arc lengths, arc orientations, angular separation between two arcs, reconstruction slice spacing, and number of arcs. The shifts determined from DTS-to-CT registration were compared to the shifts based on CBCT-to-CT registration. The difference between these shifts was used to evaluate the software accuracy. After findings were quantified, optimal parameters for the clinical use of DTS technique were determined. It was determined that at least two arcs were necessary for accurate 3D registration for patient setup. Registration accuracy of 2 mm was achieved when the reconstruction arc length was > 5° for clips with HU ≥ 1000; larger arc length (≥ 8°) was required for very low HU clips. An optimal arc separation was found to be ≥ 20° and optimal arc length was 10°. Registration accuracy did not depend on DTS slice spacing. DTS image reconstruction took 10-30 seconds and registration took less than 20 seconds. The performance of Varian DTS software was found suitable for the accurate setup of breast cancer patients. Optimal data acquisition and registration parameters were determined.
منابع مشابه
Optimization of 3D Planning Dosimetry in a Breast Phantom for the Match Region of Supraclavicular and Tangential Fields
Introduction: The complex geometry of breast and also lung and heart inhomogeneities near the planning target volume (PTV) result in perturbations in dose distribution. This problem can result in overdosage or underdosage in the match region of the three treatment fields. The purpose of this study is to create a homogeneous dose distribution in the match region between the supraclavicular and t...
متن کاملMeasurement of Thyroid Dose by TLD arising from Radiotherapy of Breast Cancer Patients from Supraclavicular Field
Background: Breast cancer is the most frequently diagnosed cancer and the leading global cause of cancer death among women worldwide. Radiotherapy plays a significant role in treatment of breast cancer and reduces locoregional recurrence and eventually improves survival. The treatment fields applied for breast cancer treatment include: tangential, axillary, supraclavicular and internal mammary ...
متن کاملDetermination of the optimal matching position for setup images and minimal setup margins in adjuvant radiotherapy of breast and lymph nodes treated in voluntary deep inhalation breath-hold
BACKGROUND Adjuvant radiotherapy (RT) of left-sided breast cancer is increasingly performed in voluntary deep inspiration breath-hold (vDIBH). The aim of this study was to estimate the reproducibility of breath-hold level (BHL) and to find optimal bony landmarks for matching of orthogonal setup images to minimise setup margins. METHODS 1067 sets of images with an orthogonal setup and tangenti...
متن کاملDesigning and validating an information management software for breast cancer treatment
Background and Aim: Breast cancer is the most common type of cancer in Iran and around the world. It has been recognized as the most significant cause of cancer deaths in developing countries such as Iran. Considering the necessity of accurate and timely diagnosis of this disease, the aim of this research was to design and validate an information management software for the treatment of breast ...
متن کاملAssessment of quality of handwritten discharge tickets of breast cancer patients: the gaps are wide and need remedy.
BACKGROUND Discharge tickets (DTs) convey important details related to hospitalization period and follow-up instructions. Therefore, quality of DTs may have significant bearing on subsequent patient care. AIMS, SETTING AND DESIGN: Aim of this retrospective study was to assess quality of handwritten DTs of breast cancer patients admitted at this institution. METHODS AND MATERIAL DTs of 736 bre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 13 شماره
صفحات -
تاریخ انتشار 2012