A review of local antibiotic implants and applications to veterinary orthopaedic surgery.
نویسندگان
چکیده
In the face of increasing incidence of multi-drug resistant implant infections, local antibiotic modalities are receiving increased attention for both infection prophylaxis and treatment. Local antibiotic therapy that achieves very high antibiotic drug concentrations at the site of the implant may represent an avenue for treatment of biofilm-forming bacterial pathogens. Randomized controlled trials in human patients have demonstrated an infection risk reduction when antibiotic-impregnated cement is used for infection prophylaxis in implanted joint prostheses, and when a gentamicin-impregnated collagen sponge is used for infection prophylaxis in midline sternotomy. The other modalities discussed have for the most part yet to be evaluated in randomized controlled trials in veterinary or human patients. In general, the in vivo pharmacokinetics and appropriate dosing profiles for local antibiotic modalities have yet to be elucidated. Toxicity is possible, and attention to the dose applied is warranted.
منابع مشابه
The treatment of chronic osteomyelitis with a biodegradable antibiotic-impregnated implant.
The use of local antibiotics from a biodegradable implant for chronic osteomyelitis is an attractive alternative. The implant delivers high tissue levels, obliterates dead space, aids bone repair and does not need to be removed. The purpose of this paper is to review our early clinical experience with custom-made calcium sulfate (Osteoset bone void filler) antibiotic-impregnated implants.
متن کاملRevision of Anatomic Total Shoulder Arthroplasty to Hemiarthroplasty: Does it work?
Background: The projected increase in revision shoulder arthroplasty has increased interest in the outcomes of theseprocedures. Glenoid component removal and conversion to a hemiarthroplasty (HA) is an option for aseptic glenoidloosening after anatomic total shoulder arthroplasty (aTSA).Methods: We identified patients who had undergone revision shoulder arthroplasty over a 15-...
متن کاملFabrication of Porous Segments Using Ti-6Al-4V Chips for Orthopaedic Applications
Different methods have been evaluated for manufacturing the porous Ti6Al4V alloys according to decreasing stress shielding phenomenon and increasing mechanical compatibility between the metallic components and the host tissue. For this purpose, in this work Ti6Al4V alloy chips were pressed under 400 MPa pressure and then samples were categorized and heated into two groups at 1000 and 1150℃ unde...
متن کاملMolecular engineering of an orthopaedic implant: from bench to bedside.
The use of metallic implants has revolutionised the practice of orthopaedic surgery. While the safety and biocompatibility of these devices are excellent, a small percentage becomes infected. These infections are due to the formation of a biofilm that harbours bacteria encased in a complex extracellular matrix. The matrix serves as a barrier to immune surveillance as well as limiting the biocid...
متن کاملImplant Removal Matrix for the Upper Extremity Orthopedic Surgeon
Orthopedic implant removal is a commonly performed procedure. While implant removal can be associated withimproved symptoms, risks of the surgery are notable. Stripped screws, broken and retained hardware, and morbidityassociated with soft tissue compromise during difficult removal are all common. Familiarity with the instruments iscritical to procedure success. The purpose of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Veterinary and comparative orthopaedics and traumatology : V.C.O.T
دوره 26 4 شماره
صفحات -
تاریخ انتشار 2013