Toric Intraocular Lens Malposition Corrected by Lens Repositioning to Manifest Refractive Cylinder Axis in Patient with Irregular Astigmatism Due to Corneal Scar

نویسندگان

  • Riley Sanders
  • Johnny Gayton
چکیده

A case is presented of a patient with an unexpected poor visual result and subsequent correction following cataract removal surgery via phacoemulsification and intraocular lens implantation using a toric intraocular lens implant (IOL). The initial operation resulted in an uncorrected vision of 20/100 (0.70 logMAR). Retrospective analysis of the patient’s corneal topography revealed irregular astigmatism secondary to remote trauma to the cornea. The cylinder axis on manifest refraction (MR) was significantly different from measured keratometry, so a second procedure was performed to align the cylinder axis of the IOL with the steep axis on MR. This repositioning procedure improved visual outcome to a final uncorrected vision of 20/25 (0.10 logMAR) and best corrected acuity of 20/20 (0.0 logMAR).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Toric intraocular lens outcome using the manufacturer's prediction of corneal plane equivalent intraocular lens cylinder power.

OBJECTIVES To describe the refractive outcome of toric intraocular lens (IOL) implantation by comparing the postoperative refractive astigmatism with the preoperative keratometric astigmatism target. METHOD In a university department of a publicly funded hospital, 38 eyes of 29 patients underwent routine cataract surgery with insertion of a toric implant (SN60TT AcrySof Toric). Surgically ind...

متن کامل

Correction of irregular and induced regular corneal astigmatism with toric IOL after posterior segment surgery: a case series

BACKGROUND Toric intraocular lens (IOL) implantation can be an effective method for correcting corneal astigmatism in patients with vitreoretinal diseases and cataract. Our purpose is to report the outcome of toric IOL implantation in two cases - a patient with scleral-buckle-induced regular corneal astigmatism and a patient with keratoconus following pars plana vitrectomy. As far as we are awa...

متن کامل

High-cylinder toric intraocular lens implantation versus combined surgery of low-cylinder intraocular lens implantation and limbal relaxing incision for high-astigmatism eyes

Clinical outcomes were compared between high-cylinder toric intraocular lens (IOL) implantation and the combined surgery of low-cylinder toric IOL implantation and limbal relaxing incision (LRI) for correcting preexisting high-amplitude corneal astigmatism. Fifty-seven eyes with preexisting corneal astigmatism of 2.5 diopter (D) or greater were divided into the following two groups: (1) eyes th...

متن کامل

Toric intraocular lenses for correction of astigmatism in keratoconus and after corneal surgery

PURPOSE To describe the results of cataract extraction with toric intraocular lens (IOL) implantation in patients with preexisting astigmatism from three corneal conditions (keratoconus, postkeratoplasty, and postpterygium surgery). METHODS Cataract patients with topographically stable, fairly regular (although sometimes very high) corneal astigmatism underwent phacoemulsification with implan...

متن کامل

Comparative rotational stability of single-piece open-loop acrylic and plate-haptic silicone toric intraocular lenses.

PURPOSE To prospectively compare the early rotational stability of AcrySof SN60T toric intraocular lenses (IOLs) with that in a retrospective series of AA4203 toric IOLs. SETTING Private practice, Los Altos, California, USA. METHODS One hundred consecutive eyes with an AcrySof SN60T(3, 4, or 5) toric IOL were compared with a consecutive series of 90 AA4203 (TL or TF) toric IOLs. The same su...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015