Robotic radiosurgery with noncylindrical collimators.
نویسندگان
چکیده
In radiosurgery, a moving beam of radiation acts as an ablative surgical instrument. Conventional systems for radiosurgery use a cylindrical radiation beam of fixed cross section. The radiation source can be moved only along simple, standardized paths. A new radiosurgical system based on a six-degree-of-freedom robotic arm has been developed to overcome limitations of conventional systems. We address the following question: Can dose distributions generated by robotic radiosurgery be improved by using noncylindrical radiation beams? This includes static noncylindrical collimators and collimators of adaptable cross section. Geometric methods for planning the shape of the beam in addition to planning beam motion are developed. Design criteria considered in this context are treatment time, radiation penumbra, and transparency of interactive treatment planning. An experimental evaluation compares distributions generated with our new radiosurgical system using cylindrical beams to distributions generated with beams of adaptable, noncylindrical shapes.
منابع مشابه
Clinical usefulness of MLCs in robotic radiosurgery systems for prostate SBRT
Stereotactic body radiation therapy (SBRT) using recently introduced multileaf collimators (MLC) is preferred over circular collimators in the treatment of localized prostate cancer. The objective of this study was to assess the clinical usefulness of MLCs in prostate SBRT by comparing the effectiveness of treatment plans using fixed collimators, variable collimators, and MLCs and by ensuring d...
متن کاملA method to improve dose gradient for robotic radiosurgery
For targets with substantial volume, collimators of relatively large size are usually selected to minimize the treatment time in robotic radiosurgery. Their large penumbrae may adversely affect the dose gradient around the target. In this study, we implement and evaluate an inner-shell planning method to increase the dose gradient and reduce dose to normal tissues. Ten patients previously treat...
متن کاملComparison of measured and Monte Carlo calculated dose distributions from “circular collimators” for radiosurgical beams
Background: Stereotactic radiosurgery is an important clinical tool for the treatment of small lesions in the brain, including benign conditions, malignant and localized metastatic tumors. A dosimetry study was performed for Elekta ‘Synergy S ’ as a dedicated Stereotactic radiosurgery unit, capable of generating circular radiation fields with diameters of 1-5 cm at isocentre using the BEAM/EGS4...
متن کاملMeasurements of the relative output factors for CyberKnife collimators.
OBJECTIVE To determine accurately the relative output factors, defined as the ratio of the nominal dose rate for a given collimator to that of the 60-mm collimator. This is particularly important for radiosurgical treatment of functional disorders, such as trigeminal neuralgia, in which a single large radiation dose is delivered to the target with a small collimator, such as the 5-mm collimator...
متن کاملThe design, physical properties and clinical utility of an iris collimator for robotic radiosurgery.
Robotic radiosurgery using more than one circular collimator can improve treatment plan quality and reduce total monitor units (MU). The rationale for an iris collimator that allows the field size to be varied during treatment delivery is to enable the benefits of multiple-field-size treatments to be realized with no increase in treatment time due to collimator exchange or multiple traversals o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Computer aided surgery : official journal of the International Society for Computer Aided Surgery
دوره 2 2 شماره
صفحات -
تاریخ انتشار 1997