[Separation of racemic flavonoids by high performance liquid chromatography using chiral mobile phase additive].

نویسندگان

  • Yanan Sun
  • Tong Li
  • Chen Ma
چکیده

To perform chiral separation of three flavonoid racemates, including dihydrodaidzein, equol and alpinetin, a simple and effective method was developed by using sulfobutyl ether-beta-cyclodextrin (SBE-beta-CD) as a mobile phase additive in HPLC system. The effects of different factors on the chiral separation were investigated, including cyclodextrin (CD) types (alpha-CD, gamma-CD, beta-CD, methyl beta-CD), CD concentration (5, 10, 20 mmol/L), pH value, nature of organic solvents (methanol, ethanol, acetonitrile) and phosphate buffer concentration. The analysis was carried out on a Kromasil 100-5C18 column (250 mm x 4.6 mm, 5 microm). The mobile phase consisted of acetonitrile and 10 mmol/L SBE-beta-CD aqueous solution( containing 20 mmol/L KH2PO4, at pH 4.0 adjusted with phosphoric acid) (20: 80, v/v). The flow rate was set at 1 mL/min, the column temperature was 25 degrees C, and the UV detections of dihydrodaidzein, equol and alpinetin were carried out at 276, 280 and 290 nm, respectively. The established method was able to separate the three racemates, and the resolutions of the enantiomers (dihydrodaidzein, equol and alpinetin) were 1.8, 1.9 and 1.4, respectively. This method might be applied to separate various types of flavanoid enantiomers in chemical structure.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Separation of Sedative – Hypnotic Drugs with Mixed Micellar Liquid Chromatography

Separation of ten sedative- hypnotic drugs was performed by RP-HPLC using mixed micellar mobile phase. Effect of temperature, type and amount of organic modifier in mobile phase on efficiency (N) and asymmetry factor (B/A) showed that, the appropriate conditions for a good separation were 35°C and 7% (V/V) butanol in mobile phase.  Variations of selectivity factor versus butanol concent...

متن کامل

SEPARATION OF POLYCYCLIC AROMATIC HYDROCARBONS WITH MIXED MICELLAR HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Separation of Polycyclic Aromatic Hydrocarbons was performed by RP-HPLC using mixed micellar mobile phase. Effect of temperature, types and amounts of coorganic solvent in mobile phase on efficiency, asymmetry factor and selectivity factor showed that the appropriate condition for separation of these compounds was 3% isopropanol (V/V) as co-organic solvent in mobile phase at 40°C. Analysis of...

متن کامل

Review High-performance liquid chromatographic enantioseparation of drugs containing multiple chiral centers on chiral stationary phases

In recent years there has been considerable interest in the synthesis and separation of enantiomers of organic compounds especially because of their importance in the biochemistry and pharmaceutical industry. High-performance liquid Chromatography is a very useful method for the direct separation of enantiomers. However, about 30−40 years ago, commercially available chiral stationary phases wer...

متن کامل

Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column

The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...

متن کامل

Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column

The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Se pu = Chinese journal of chromatography

دوره 31 5  شماره 

صفحات  -

تاریخ انتشار 2013