Peripheral prism glasses: effects of dominance, suppression, and background.
نویسندگان
چکیده
PURPOSE Unilateral peripheral prisms for homonymous hemianopia (HH) place different images on corresponding peripheral retinal points, a rivalrous situation in which local suppression of the prism image could occur and thus limit device functionality. Detection with peripheral prisms has primarily been evaluated using conventional perimetry, where binocular rivalry is unlikely to occur. We quantified detection over more visually complex backgrounds and examined the effects of ocular dominance. METHODS Detection rates of eight participants with HH or quadranopia and normal binocularity wearing unilateral peripheral prism glasses were determined for static perimetry targets briefly presented in the prism expansion area (in the blind hemifield) and the seeing hemifield, under monocular and binocular viewing, over uniform gray and more complex patterned backgrounds. RESULTS Participants with normal binocularity had mixed sensory ocular dominance, demonstrated no difference in detection rates when prisms were fitted on the side of the HH or the opposite side (p > 0.2), and had detection rates in the expansion area that were not different for monocular and binocular viewing over both backgrounds (p > 0.4). However, two participants with abnormal binocularity and strong ocular dominance demonstrated reduced detection in the expansion area when prisms were fitted in front of the non-dominant eye. CONCLUSIONS We found little evidence of local suppression of the peripheral prism image for HH patients with normal binocularity. However, in cases of strong ocular dominance, consideration should be given to fitting prisms before the dominant eye. Although these results are promising, further testing in more realistic conditions including image motion is needed.
منابع مشابه
Community-based trial of a peripheral prism visual field expansion device for hemianopia.
OBJECTIVE To determine the functional utility for general mobility of peripheral prism glasses, a novel visual field expansion device for hemianopia, in a large-scale, community-based, multicenter study with long-term follow-up. METHODS Forty-three participants with homonymous hemianopia were fitted with temporary press-on Fresnel peripheral prism segments of 40 prism diopters. Follow-up ques...
متن کاملClinical and laboratory evaluation of peripheral prism glasses for hemianopia.
PURPOSE Homonymous hemianopia (the loss of vision on the same side in each eye) impairs the ability to navigate and walk safely. We evaluated peripheral prism glasses as a low vision optical device for hemianopia in an extended wearing trial. METHODS Twenty-three patients with complete hemianopia (13 right) with neither visual neglect nor cognitive deficit enrolled in the 5-visit study. To ex...
متن کاملClinical Study A Pilot Evaluation of On-Road Detection Performance by Drivers with Hemianopia Using Oblique Peripheral Prisms
Aims. Homonymous hemianopia (HH), a severe visual consequence of stroke, causes difficulties in detecting obstacles on the nonseeing (blind) side. We conducted a pilot study to evaluate the effects of oblique peripheral prisms, a novel development in optical treatments for HH, on detection of unexpected hazards when driving. Methods. Twelve people with complete HH (median 49 years, range 29–68)...
متن کاملRandomized crossover clinical trial of real and sham peripheral prism glasses for hemianopia.
IMPORTANCE There is a major lack of randomized controlled clinical trials evaluating the efficacy of prismatic treatments for hemianopia. Evidence for their effectiveness is mostly based on anecdotal case reports and open-label evaluations without a control condition. OBJECTIVE To evaluate the efficacy of real relative to sham peripheral prism glasses for patients with complete homonymous hem...
متن کاملA Pilot Evaluation of On-Road Detection Performance by Drivers with Hemianopia Using Oblique Peripheral Prisms
Aims. Homonymous hemianopia (HH), a severe visual consequence of stroke, causes difficulties in detecting obstacles on the nonseeing (blind) side. We conducted a pilot study to evaluate the effects of oblique peripheral prisms, a novel development in optical treatments for HH, on detection of unexpected hazards when driving. Methods. Twelve people with complete HH (median 49 years, range 29-68)...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Optometry and vision science : official publication of the American Academy of Optometry
دوره 89 9 شماره
صفحات -
تاریخ انتشار 2012