Air-CT cisternography and canalography for small acoustic neuromas.
نویسندگان
چکیده
Disenchantment with the limitations, and in some cases the morbidity, of currently used radiologic techniques for the demonstration or exclusion of small acoustic neuromas prompted development of an examination using small amounts of intrathecal air and computed tomography (CT). A prospective study was designed to evaluate air CT cisternography/canalography, wherein patients with the clinical symptoms of acoustic neuroma but with negative enhanced CT, were evaluated by metrizamide CT cisternography followed by air CT cisternography/canalography. Pantopaque cisternography was then performed as a control procedure. Four patients had surgically proven tumors. In 13 others, accumulated evidence indicated no tumors were present. Results suggest that air-CT cisternography is superior to all other diagnostic methods in defining small acoustic neuromas, and may exclude an intracanalicular lesion without the potential hazards of Pantopaque cisternography or high concentration metrizamide tomocisternography. With air-CT cisternography, there were no errors in this series.
منابع مشابه
Arachnoiditis simulating acoustic neuroma on air-CT cisternography.
Routine thin-sect ion CT after contrast enhancement may fail to demonstrate smal l acoustic neuromas, usually those smaller than 10 mm [1, 2]. Metrizamide CT cisternography has demonstrated such small acoustic neuromas, but cannot demonstrate an intracanalicular tumor accurately [3]. Pantopaque c isternography can demonstrate an intracanalicular mass, but has a high percentage of inconclusive e...
متن کاملAcoustic neuromas: evaluation by magnetic resonance imaging.
Proton magnetic resonance imaging (MRI) examinations were performed in six patients with seven acoustic neuromas, and the results were compared with conventional tomography of the internal auditory canals, contrast-enhanced computed tomography (CT), and air CT cisternography. All tumors were identified with MRI. The three largest tumors (greater than 1 cm diameter) looked similar to the tumors ...
متن کاملAir CT cisternography of anterior inferior cerebellar artery loop simulating an intracanalicular acoustic neuroma.
Acoustic neuromas larger than 1 cm are usually apparent on routine computed tomography (CT) after contrast enhancement, but smaller lesions escape detection [1, 2]. Metrizamide CT cisternography can demonstrate small lesions, but it is not accurate for the detection of intracanalicular lesions [1, 3]. Pantopaque meatocisternography can detect intracanalicular lesions but has a high percentage o...
متن کاملCT in Diagnosis of Acoustic Neuromas 645
A detailed analysis of the CT findings in 75 cases of acoustic neuroma is presented. The method of examination included plain and enhanced CT, metrizamide CT cisternography (M-CTC), and gas CT cisternography (gas-CTC). The common CT appearances of acoustic neuromas were as follows: 93.6% appeared as isodense or hypodense on precontrast scan; homogeneous enhancement was observed in 53.8% on post...
متن کاملSmall acoustic neuromas: detection by high resolution gas CT cisternography.
Experience with 81 gas computed tomography (CT) cisternography procedures in 79 patients in searching for acoustic neuroma is reported. Twenty-one tumors, four exclusively intracanalicular, were demonstrated after standard contrast-enhanced CT was negative. Fifty-five examinations were negative; four were inconclusive. The high resolution scanner with digital localization and reconstruction zoo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 1 1 شماره
صفحات -
تاریخ انتشار 1980